11
RUNNING MANUAL
TenarisHydril
IDM Code GDL37413/0 / Mar
ch 2020
CONNECTION SPECIFIC RUNNING GUIDELINES
T
enarisHydril EasyDock™ Connection
8.
Ensure ARK(s) are in the unlocked position prior to
stabbing.
9.
Apply Low gear and make up below 5 RPM but no
slower than 2 RPM.
10.
Apply the torque indicated in the appropriate data
sheet ensuring an acceptable make up is attained as
previously described.
11.
Slacken the fixing bolt on the open ARK(s) and
hammer into position.
12.
Tighten ARK bolt to lock in position.
13.
Once assembled scribe a longitudinal line across
both connectors as visual reference.
14.
If a situation arises where an O-ring and/or ARK(s)
requires replacing, do so away from well bore.
Anti Rotation Key (ARK) Function
1.
ARKs are intended to be used for multiple
installations if required, but this is only possible if they
are properly handled, used and stored.
2.
If an ARK is damaged it should be replaced with a
new one.
3.
To activate, completely loosen lock bolt and knock
into place with a hammer, slide sledge or other such
device.
4.
Ensure all hammer blows contact the ARK strike face
parallel to the face. Glancing blows or angled strikes
can cause damage or break the ARK.
5.
Hammer the ARK in the direction of travel only.