12
RUNNING MANUAL
TenarisHydril
CONNECTION SPECIFIC RUNNING GUIDELINES
T
enarisHydril EasyDock™ Connection
6.
Stop hammering the ARK as soon as it is fully set to
prevent breakage.
7.
Ensure the ARK(s) are locked in place by the lock
bolt using a hexagonal key.
8.
Correct and incorrect methods of setting/ un-setting
the ARK are indicated in the following diagrams.
Setting:
90°
45°
45°
9.
The use of a chisel and hammer to unset the ARK is
required
10.
The chisel should be placed correctly in the removal
slot to prevent damaging the ARK or slot edges.
11.
Hammer the ARK in the direction of travel only.
12.
Correct and incorrect de-activation methods are
indicated in the following diagrams.