CHAPTER 6: PartReplacementGuide
36
6.7
MOTOR CONTROL BOARD (MCB) REPLACEMENT
1) Turn off power and disconnect the cord from the machine.
2) Remove the motor cover as outlined in Section 6.1.
3) Disconnect the wire connectors at the MCB.
4) Remove the 2 screws holding each side of the MCB to the frame (Figures A).
FIGURE A
FIGURE B
5) Remove the MCB (Figure B)
6) Reverse Steps 1-5 to install a new MCB. Make sure that all wires removed during Step 3 are re-connected.