28
Sidekick
®
Plus Test Set
To change the measurement, use the following function
keys:
•
F1 T-G
to access tip-to-ground measurement.
•
F2 R-G
to access ring-to-ground measurement.
•
F3 REV
to reverse polarity.
•
F4
selects between 3 ranges:
R x 1k measures up to 1MΩ
R x 10k measures up to 100 MΩ
R x 100k measures up to 999 MΩ
To exit the LEAKAGE function, move the rotary knob
to another position or press the
Fn
key to access
resistance measuring.
Leakage specifications are as follows:
• Range: 0 to 999 MΩ
• Resolution:
1 kΩ to 1 MΩ
10 kΩ from 1 MΩ to 10 MΩ
100 kΩ from 10 MΩ to 100 MΩ
1 MΩ from 100 MΩ to 999MΩ
• Accuracy: ±3%
OHMS
To perform this measurement, follow these steps:
1. Connect the test leads: black to tip, red to ring, and
green to ground.
2. Move the rotary knob to the LEAKAGE/OHMS
position.
3. Press the
Fn
key to access the Resistance screen.
The initial LCD screen displays single pair resistance
for tip-to-ring. The function keys have the following
choices:
•
F1 T-G
to access tip-to-ground measurement.
•
F2 R-G
to access ring-to-ground measurement.
•
F3 3-Lead
to display all three leads.
•
F4 Compensate
to measure ohms when foreign DC
voltage is detected.
To exit the OHMS function, move the rotary knob to
another position or press the
Fn
key to access the
leakage measurement.