- 7 -
SETTING UP
The Shadow Nightfall should be located on a secure, solid surface such as the floor. The machine can
operate in any orientation from 45 degrees upwards to 45 degrees downwards. Take precautions to
avoid fluid spills if the machine is oriented at an angle.
Fluid Set Up
Only use genuine Rosco Smoke Simulation fluid in your Nightfall machine. The use of any other fluid will void your
warranty, may damage the equipment, and may cause health hazards.
For convenience, the Nightfall is designed with an integral compartment that will hold a 4-Litre or 5-Litre
bottle of smoke fluid. Place the fluid bottle into the compartment. Feed the fluid inlet hose into the bottle
of smoke fluid, ensuring that the filter, located at the end of the tube is fully submerged in fluid. Slide the
bottle cap along the tube and tighten the cap onto the bottle. Take precautions to avoid fluid spills.
All Shadow machines are primed at the factory with a small amount of fluid. No additional priming
should be necessary for proper smoke output. If smoke output is diminished or intermittent, see the
Priming the System section of this manual for instructions on how to re-prime the fluid path.
Power Connections
Ensure that the machine is plugged into an outlet rated for the proper voltage and amperage. The
Nightfall is a 1,200 watt device and will draw 5.2A at 230 VAC or 10.9A at 115 VAC. Note: 230 volt machines
are shipped with bare leads at the end of the power cord. A proper electrical connector must be attached
based on the local power requirements. If unsure how to do this, please contact Tempest for assistance. An
example of properly wiring a UK 13A connector is shown below.
Earth Wire
Neutral Wire
Outer Insulation
Live Wire
Fuse
Cable grip