background image

- 4 -

•  Use of any fluid other than Rosco Smoke Simulation fluid or modification or attempted 
  unauthorized repair of the machine will immediately invalidate the warranty.

•  Machines are designed for continuous use over an 8-hour day, but to protect components, it is wise  
  to turn off the machine when it is not in use.   In permanent installations,  it is advisable to equip  
  the circuit with a night cut-off device.

Additional Precautions: Do’s & Don’ts

•  Do Read the entire manual before operating the machine and pay particular attention to all 
 

CAUTIONS AND WARNINGS.

•  Do Use an extension cord that is properly rated for voltage, current and length, and  is free from  
 

nicks, cuts or other signs of wear.

•  Do Check to see that the machine is clean and free of foreign objects before each  
 

operating period.

•  Do Ensure that the machine is adequately ventilated.
•  Do Use proper caution when handling hot surfaces.
•  Do Use the minimum amount of fog required to achieve the desired effect.
•  Do Not Use the machine near a person who has asthma or similar inhalation disorder.
•  Do Not Use any foreign substances in the machine.
•  Do Not Use a machine that is damaged or operating improperly in any way.
•  Do Not Use a machine that leaks fluid from the housing.
•  Do Not Leave the machine switched on for prolonged periods of time without producing fog.
•  Do Not Enclose the machine.
•  Do Not Install the machine in such a fashion that the operator cannot see the whole machine,  
 

including the indicator lights.

•  Do Not Touch the shielded nozzle of the machine. Allow sufficient cooling time after operation  
 

before attempting to perform maintenance or storage. 

•  Do Not Direct the fog output continuously against nearby surfaces.  This may eventually 
 

cause fluid to re-condense.

Danger! Hazardous 

voltage. Contact will 

cause electric shock.   

Caution! Safety 

hazard. Risk of 

personal injury.   

Caution! Burn 

hazard. Hot surface.

Do not touch   

Caution! Fire hazard. 

Danger! Hazardous 

voltage. Contact will 

cause electric shock.   

Caution! Safety 

hazard. Risk of 

personal injury.   

Caution! Burn 

hazard. Hot surface.

Do not touch   

Caution! Fire hazard. 

Safety Precautions

•  In any facility, the fog concentration should be controlled.  The fog should never mask  
  emergency exits, safety signs, staircases or other safety constructions.

•  After long use, or if the machine is not properly set, some liquid droplets or wet area  
  may appear in front of the machine’s outlet.  This liquid should be wiped up to prevent 
  a condition where someone might slip and fall.

Preventing Improper Operation

•  Unauthorized repair or alteration of any safety devices can lead to improper operation
  and accidents. Repairs should be performed only by an authorized Service Center. 

Содержание Shadow Nightfall

Страница 1: ...N i g h t f a l l...

Страница 2: ...the Detachable Remote Control Panel 8 Multi Link 8 Using the Remote Control Panel 8 Using Timers 8 9 Using Multi Link 9 Changing Fluid 9 Running Dry 10 Priming the System 10 Powering Down 10 Ducting...

Страница 3: ...Nightfall other than genuine Rosco Smoke Simulation Fluids as they have not been tested for optimal performance and safety considerations Doing so may damage the machine and will void the warranty Not...

Страница 4: ...machine that shows signs of improper use Even slight damage may be an indication of a major problem If the machine looks questionable use it only under strict observation If the machine shows any unu...

Страница 5: ...eave the machine switched on for prolonged periods of time without producing fog Do Not Enclose the machine Do Not Install the machine in such a fashion that the operator cannot see the whole machine...

Страница 6: ...et that allows for multiple machines to be daisy chained together and controlled from a single Remote Control Panel Main Power Switch Turns unit on or off by con trolling the flow of power to the unit...

Страница 7: ...s engaged Fog Level Knob Rotate to set the desired amount of smoke output Higher numbers indicate more smoke Output is controlled by pump speed increasing and sending more smoke fluid into the heat ex...

Страница 8: ...Slide the bottle cap along the tube and tighten the cap onto the bottle Take precautions to avoid fluid spills All Shadow machines are primed at the factory with a small amount of fluid No additional...

Страница 9: ...nel from the unit loosen the thumb screws and lift the panel from its recessed mount A 15 foot 4 5m cable is provided to allow the machine to be operated at a distance If needed a longer 3 pin XLR cab...

Страница 10: ...time that the machine waits before starting to produce smoke again The numeric settings on the timer knobs are relative settings and do not correspond to specific seconds or minutes See the table bel...

Страница 11: ...is shut off If the machine will be unused for an extended period of time follow the Storage and Shipment instructions listed under Maintenance to prepare the machine for long term storage DUCTING SMOK...

Страница 12: ...te Fog Level Knob clockwise Rotate the Fog Level Knob clockwise Ensure filter is submerged See the Priming the System section of the manual Contact nearest Service Center for repair Machine produces s...

Страница 13: ...sure optimal performance The Air Input Connection was designed to pro vide a fast and efficient method of cleaning the heat exchanger by purging it of residual fluid and build up using compressed air...

Страница 14: ...e continuous Warm up time 7 10 minutes Control and programming Control options timer remote Fluid system Capacity 120v 4 liters 240v 5 litres Fluid consumption 3 6 liters hour Connections Remote Multi...

Страница 15: ...14 Dimensions Dimensions are shown in inches and millimeters...

Страница 16: ...damage to the Rosco product caused by parts not manufactured distrib uted or certified by Rosco Rosco is not obligated to provide warranty service should the product fail to be properly maintained or...

Страница 17: ......

Страница 18: ...NOTES...

Страница 19: ...NOTES...

Страница 20: ...Tempest Technology Corporation 4708 N Blythe Avenue Fresno CA 93722 t 559 277 7577 f 559 277 7579 response tempest us com www tempest us com...

Отзывы: