Tempest Shadow Nightfall Скачать руководство пользователя страница 11

- 10 -

Running Dry
Do not allow the machine to run dry of fluid. If the machine does run out of fluid it will stop producing 
smoke and the green Ready Indicator light will indicate a Fluid Out condition with a fast double-flash.   
In order to reset the Fluid Out condition, power cycle the machine by turning the Main Power Switch 
off, wait 5 seconds, and then turn the Main Power Switch back on.   After inserting the tube in a new 
bottle of smoke fluid, you will need to prime the machine to remove airlocks in the fluid pipework of 
the machine. 
Priming the System
To prime the machine, turn the Fog Level Knob to Zero, then hold down the Fog Button and turn the 
knob to maximum.   Keep the button held until the smoke output is strong and steady.  Then turn the 
Fog Level knob back to the required output level and release the Fog Button.

Powering Down

After use, allow the machine to sit for several minutes before switching the Main Power Switch to off.  

Turning off the power switch during smoke production can cause damage to the heat exchanger.   Allow 

machine to cool completely before packing or storing.  Note:  The nozzle of the machine may remain hot for 

up to 10 hours after power is shut off.  

If the machine will be unused for an extended period of time, follow the Storage and Shipment instructions 
listed under Maintenance to prepare the machine for long-term storage.

DUCTING SMOKE 

It is often desirable to duct smoke from the machine to another location. This can be accomplished using 
flexible hose (“dryer hose”) or similar large diameter ducting such as 4in (100mm) PVC.  Avoid sharp bends 

in the duct, which can create turbulence or back flow.
The duct should be positioned no closer than 2in (50mm) to the nozzle.  An open airflow between the 

nozzle and opening of the duct is crucial to allow for aerosolization and create proper airflow.  Placing 

ductwork or tubing directly over the nozzle or nozzle guard will cause damage to the machine and will 

void the warranty.   Take all precautions to avoid fire hazards as the nozzle is extremely hot.
In some instances, it is desirable to use a fan to accelerate the smoke through the ductwork.   Never 
run smoke through the blades of a fan as the action of the impeller will cause condensation of fluid 

particles.   To properly use a fan, create a vent in the ducting system such as a and introduce a fan at the 

vent point. This will create a low pressure point that “pulls or pushes” the smoke through the ductwork. 

Contact Tempest for more advice on ducting smoke.

Squirrel Cage Fan

Ducting Hose

Hose Adaptor

Fog Machine

Содержание Shadow Nightfall

Страница 1: ...N i g h t f a l l...

Страница 2: ...the Detachable Remote Control Panel 8 Multi Link 8 Using the Remote Control Panel 8 Using Timers 8 9 Using Multi Link 9 Changing Fluid 9 Running Dry 10 Priming the System 10 Powering Down 10 Ducting...

Страница 3: ...Nightfall other than genuine Rosco Smoke Simulation Fluids as they have not been tested for optimal performance and safety considerations Doing so may damage the machine and will void the warranty Not...

Страница 4: ...machine that shows signs of improper use Even slight damage may be an indication of a major problem If the machine looks questionable use it only under strict observation If the machine shows any unu...

Страница 5: ...eave the machine switched on for prolonged periods of time without producing fog Do Not Enclose the machine Do Not Install the machine in such a fashion that the operator cannot see the whole machine...

Страница 6: ...et that allows for multiple machines to be daisy chained together and controlled from a single Remote Control Panel Main Power Switch Turns unit on or off by con trolling the flow of power to the unit...

Страница 7: ...s engaged Fog Level Knob Rotate to set the desired amount of smoke output Higher numbers indicate more smoke Output is controlled by pump speed increasing and sending more smoke fluid into the heat ex...

Страница 8: ...Slide the bottle cap along the tube and tighten the cap onto the bottle Take precautions to avoid fluid spills All Shadow machines are primed at the factory with a small amount of fluid No additional...

Страница 9: ...nel from the unit loosen the thumb screws and lift the panel from its recessed mount A 15 foot 4 5m cable is provided to allow the machine to be operated at a distance If needed a longer 3 pin XLR cab...

Страница 10: ...time that the machine waits before starting to produce smoke again The numeric settings on the timer knobs are relative settings and do not correspond to specific seconds or minutes See the table bel...

Страница 11: ...is shut off If the machine will be unused for an extended period of time follow the Storage and Shipment instructions listed under Maintenance to prepare the machine for long term storage DUCTING SMOK...

Страница 12: ...te Fog Level Knob clockwise Rotate the Fog Level Knob clockwise Ensure filter is submerged See the Priming the System section of the manual Contact nearest Service Center for repair Machine produces s...

Страница 13: ...sure optimal performance The Air Input Connection was designed to pro vide a fast and efficient method of cleaning the heat exchanger by purging it of residual fluid and build up using compressed air...

Страница 14: ...e continuous Warm up time 7 10 minutes Control and programming Control options timer remote Fluid system Capacity 120v 4 liters 240v 5 litres Fluid consumption 3 6 liters hour Connections Remote Multi...

Страница 15: ...14 Dimensions Dimensions are shown in inches and millimeters...

Страница 16: ...damage to the Rosco product caused by parts not manufactured distrib uted or certified by Rosco Rosco is not obligated to provide warranty service should the product fail to be properly maintained or...

Страница 17: ......

Страница 18: ...NOTES...

Страница 19: ...NOTES...

Страница 20: ...Tempest Technology Corporation 4708 N Blythe Avenue Fresno CA 93722 t 559 277 7577 f 559 277 7579 response tempest us com www tempest us com...

Отзывы: