8
Freezer.
♦
CU:
(CU:20) This example sets the upper limit of the external tempera-
ture sensor 2 to 20 degrees. If the temperature were to exceed 20 de-
grees for more than the programmed time limit, a text message would be
sent.
♦
CL:
(CL:-15) This example sets the lower limit of the external tempera-
ture sensor 2 to –15 degrees. If the temperature were to drop below –15
degrees for more than the programmed time limit, a text message would
be sent.
♦
CT:
(CT:10) This example sets the time delay of the external temperature
sensor 2 to 10 minutes. This means that once the temperature went out
of range, the monitor would wait 10 minutes before sending text alerts.
♦
CID:
(CID:Refrigerator) This example sets the name of external sensor 2
to Refrigerator.
♦
PT:
(PT:1) This example sets the power outage time to 1 minute. Once
power has been out for one minute, a text will be sent.
Note: A setting
of PT:0 will only alarm after a power outage of 3 or more seconds.
♦
WT:
(WT:1) This example in the table and parenthesis would set the
time delay of the optional water sensor to 1 minute. This means that
once the water sensor became wet a text would be sent one minute later.
♦
RT:
(RT:120) This example in the table and parenthesis would set the
reminder time to 2 hours. The monitor will continue to send text alerts
every 2 hours as long as the condition remains in alarm.
Zero is the de-
fault and is disabled when set to zero.
♦
ST:
(ST:13) This example would send a status message at 1:00 pm
every day. 0 is disabled, therefore you cannot receive a status update at
midnight. Status contains everything the ? Query returns.
♦
D1:
(D1:2) This example in the table and parenthesis would set the time
delay of the optional door sensor 1 to 2 minutes. This means that a text
would be sent after the door was open for two minutes. To disable a
door sensor, set the delay to
999
. D1:
999 (default)
♦
1ID
: (ID:Front Door) This example sets the 1st door sensor name to
Front Door.
♦
D2:
(D2:2) This example in the table and parenthesis would set the time
delay of the optional door sensor 2 to 2 minutes. This means that a text
would be sent after the door was open for two minutes. To disable a
door sensor, set the delay to
999
. D2:
999 (default)
♦
2ID:
(2ID:Garage Door) This example sets the 2nd door sensor name to
Garage Door.
♦
PW:
(PW:5964) This example in the table and in parenthesis would set
the password of the monitor to 5964. This means that any further texts or
emails sent to the monitor should include on the first line the number
5964. It can be any 4 digits or letters
. Letters are case sensitive.
♦
CPW:
(CPW:5964) This example in the table and in parenthesis would
clear the password of the monitor which was set to 5964 in the previous
example.