The CM705E is an environmental monitor with built in Ethernet (wired or wireless) and 
Cellular alarming and reporting capabilities.  This unit can monitor up to eight temperature 
sensors, power, and four dry contact inputs, in addition to its optional built in temperature 
and humidity sensor.  Alarms are sent via the cellular modem as text messages.  Our Data 
Capture Software running on a PC can also send text messages as well as email alerts.  
Data Capture also collects data and stores it on the computer.  The unit also stores up to 6 
months worth of data in its internal memory, which can be retrieved using the free program 
TG Status or Data Capture.  

Programming the CM705E is accomplished via Data Capture 5 or later software.

http://www.temperatureguard.com/software.html

Once the unit has been wired to all appropriate sensors, connected to the Ethernet
network, and is registered on the cellular network, programming should be completed.  

For GSM units (AT&T)
FCC ID:  RI7LE910NAV2 
IC: 5131A-LE910NAV2

For Verizon units.
FCC ID: RI7LE910SV
IC:5131A-LE910SV

For Combo units (shipped after 01/25/2020 rev 11 or higher)
FCC ID: RI7LE910CxNF
IC:5131A-LE910CxNF

For wireless Ethernet units
FCC ID: R68XPICOW 
IC: 3867A-XPICOW 

Page 

2

 of 

8

Содержание CM705E

Страница 1: ...ex Page Number General Description and part numbers 2 Installation 3 Wiring Diagram 3 Testing the programmed numbers 4 Sensors 4 Checking Status 4 Daily Status 4 What is an alarm condition 4 LCD Screen and Cancel Alarm Push button 5 6 Helpful Hints 7 DHCP wired version 7 DHCP wireless version 7 Part Numbers 8 ...

Страница 2: ...uter The unit also stores up to 6 months worth of data in its internal memory which can be retrieved using the free program TG Status or Data Capture Programming the CM705E is accomplished via Data Capture 5 or later software http www temperatureguard com software html Once the unit has been wired to all appropriate sensors connected to the Ethernet network and is registered on the cellular networ...

Страница 3: ...chased with the network adapter Use only the provided 5VDC power adapter Wire all inputs to be used Wiring diagram below Page 3 of 8 CM705E 1v Sensor 1 1 Sensor 8 Dry Contact Inputs v 2 Wiring Diagram side view of enclosure Alarm Relay Output T22 NO T23 NC T24 Common 1 24 DC 5V ON OFF 3 4 ...

Страница 4: ...s the daily stats will say all sensors are within limits If one or more sensors are out of limits it will report the out of limits sensors and the condition temperature humidity open closed etc What is an alarm condition An alarm condition is anytime a sensor exceeds the upper or lower limit for longer than the programmed time delay Once an alarm occurs the buzzer will start beeping three loud bee...

Страница 5: ...rical order To silence the buzzer press and hold the cancel alarm button while the in alarm sensor screen is showing Under normal operation the main LCD screen will be shown Main Screen Second Screen This screen displays the internal sensor current temperature and humidity cellular module status signal strength and battery voltage after pressing the cancel alarm button once You can also scroll thr...

Страница 6: ...losed an open square is an open input Top square is Input 1 second is Input 2 etc If the input is set to water sensor the open square is no water detected the closed square is a wet condition The inputs are not displayed in the scroll through menu unless they are in alarm Sensor 2 is below the lower limit Page 6 of 8 ...

Страница 7: ... down The screen will display Reset to DHCP No Pressing and releasing the button again will toggle the No to Yes Let it boot up while the Yes is dis played and it will be in DHCP mode How do I set the Guard to DHCP wireless version The CM705E cover must be removed Power the unit on When it has completely booted up press the Reset_Defaults button for 6 seconds or until the led goes out Please note ...

Страница 8: ... Ethernet model shipped without a sim card Unit will work on the Verizon network only Add NIST to the part number for calibration certificate New feature added to Rev 17 and higher 04 15 2021 The phone numbers can now be programmed by text message and checked by text message There are 4 available numbers that can be programmed Example To program the 1st number send a text to the unit with the mess...

Отзывы: