Important Safeguards

Although your gas logs are very realistic in appearance it
is not a real wood-burning fireplace and must be used for
burning rejected material.

To avoid irreparable damage to the appliance or personal
injury; matches, paper, garbage or any other material must not
be placed or thrown on top of the logs or into the flames.

To avoid personal injury, do not touch hot surfaces when
the appliance is operating.

Touch only the piezo button and control knob. Avoid contact
with the front screen, canopy or any other part which will be
very hot.

Always ensure that the fireplace screen is in place

when the appliance is operating.

Close supervision is necessary when the appliance is
being operated near children.

Do not use to cook food.

If this is the ONLY gas appliance, we recommend a minimum
200 pound cylinder with a fill gauge.  Use of a 100 pound
cylinder is not recommended. Other household gas appliances
may require the tank size to be larger. Do not operate the vent
free fireplace if the fuel level in the propane tank is below 1/4
full.

This appliance is intended to be used only for supplemental
heat. Do not use it routinely as a primary heat source. Continu-
ous operation could produce excessive humidity depending on
construction characteristics and outdoor temperatures (below
200

°

F) Over time, this could cause condensation to form and

damage wall structures and exterior paint.  Do not use this
product during building construction.  Dust, debris, paint fumes
etc. can cause burner damage and/or produce strong odors.

If the fireplace is equipped with glass doors, the doors must be
fully open when the gas appliance is operating.

WARNING: The glowing ember base and all the logs are
manufactured from bonded ceramic fiber. This is a
commonly used material in industry worldwide. In the
event of the logs and base being removed, care should
be taken not to damage the bonded material.

Intentional misuse of, or deliberately fragmenting, the
material could lead to inhaling fibers and be injurious to
health.  Insure the logs are properly positioned at all
times.

Match Lighting

If the pilot cannot be ignited with the piezo, it can be manually
lit with the use of a match and lighter rod.

1. Place the match in the holder and light.  With the right

hand, depress and turn the control knob counterclockwise

  to the PILOT position.  Hold in for 20 seconds.

2. Take the lighter rod and lighted match and ignite the pilot.

3. Continue to hold the control knob for an additional 20

seconds to ensure pilot is maintained.

Flame Check

A periodic visual check of the flames should be made. The pilot
flame should always be present when the appliance is in
operation. (Fig. 17)

In normal operation (at full rate for approximately 15 minutes)
the following flame appearance should be observed:

The flame should burn blue with some yellow  flames visible.
Height of the blue flame should be approximately 1” on high.
The yellow flames should extend 6 to 8 inches above the large
front log.

Typical flame shape seen in Figure 18.

NOTE: For your safety, the appliance is equipped with an
oxygen depletion system. The system senses the oxygen in the
atmosphere and switches off the gas supply in case the level of
oxygen falls below a safe level. It must not be altered in any
way.

1

¹⁄₂

"

1

¹⁄₂

"

Natural Gas

Propane

T122

Fig. 17  Pilot flame position and location.

TL108

Fig. 18  Correct burner flame appearance.

A

Air Shutter Settings

Model

A

VFL34RN

Closed

VFL34RP

0.375”

T134

Fig. 19  Air shutter settings.

Содержание VFL34MN

Страница 1: ...es air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Section Provisions For Adequate Combustion and Ventilation Air Page 4 FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do n...

Страница 2: ...ighting 13 Flame Check 13 Managing Heat Output 14 Maintenance Cleaning 14 Troubleshooting 15 Servicing 15 Repair Parts 16 Warranty Information 17 Installation and Startup Checklist 18 Warranty Registration 20 Table of Contents Minimum Dimensions for Existing Solid Fuel Burning Fireplaces This appliance may be installed in an aftermarket permanently located manufactured mobile home where not prohib...

Страница 3: ...DO NOT use this heater in recreational vehicles bedrooms or bathrooms If this is the ONLY gas appliance we recommend a minimum 200 pound cylinder with a fill gauge Use of a 100 pound cylinder is not recommended Other household gas appliances may require the tank size to be larger Do not operate the vent free heater if the fuel level in the propane tank is below 1 4 full DO NOT use this heater if a...

Страница 4: ...e Example Space size 25 length x 25 width x 8 ceiling height 5 000 cu ft volume of space If additional ventilation from adjoining room s is supplied with grills or doorless openings add the volume of these rooms to compute the total volume of the applicable space 2 Divide the space volume by 50 cubic feet to determine the maximum BTU Hr the space can support ________ volume of space 50 cu ft Maxim...

Страница 5: ...onal Fuel Gas Code NFPA 54 ANSI Z223 1 Section 5 3 Air for Combustion and Ventilation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermostat controlled power vent Heated air entering the attic will activate the power vent L W D Flue Damper Closed for Unvented Operation and Maximum Heat Output Flue Damper Locke...

Страница 6: ... do so could cause gas leaks Holes are provided in the sheet metal chassis Fig 3 and should be used for securing the log set After locating the chassis correctly in the fireplace mark the hole positions on the fireplace floor Drill two 1 8 diameter holes approximately 1 2 deep Use the two screws to secure the chassis to the fireplace floor Fig 3 Clearances NOTE The following instructions regarding...

Страница 7: ...ol valve gas line inlet The inlet to these units is 1 2 NPT If installation is for L P gas have L P installer use two stage regulation and make all connections from storage tank to heater Refer to the National Fuel Gas Code for the proper supply tank size with the Btu s Hr requirements If this is the ONLY gas appliance we recommend a minimum 200 pound cylinder with a fill gauge Use of a 100 pound ...

Страница 8: ... for specific requirements Piped Gas Supply Drop Manual Shut Off Valve Horizontal Ground Joint Union Tee Fitting Nipple 3 Min Cap 1 8 N P T Plugged Hole for Test Gauge Gas Valve Drop Manual Shut Off Valve Ground Joint Union Tee Fitting Nipple 3 Min Cap 1 8 N P T Plugged Hole for Test Gauge Gas Valve Tubing Gas Supply Riser Manual Shut Off Valve Ground Joint Union Tee Fitting Nipple 3 Min Cap 1 8 N...

Страница 9: ... 7 0 w c 11 0 w c Min 5 0 w c 10 8 w c Regulator Pressure 3 5 w c 10 0 w c Minimum inlet supply pressure for the purpose of input adjustment Gas Pressure Check The gas inlet pressure specified in Table 1 is the pressure where the field installed gas line connects to the gas control This is measured at the inlet test port on the gas valve in the appliance Ensure that pressure is as shown in Table 1...

Страница 10: ...c ash on burner pilot or logs 6 Platinum embers are to be placed only on top of the front burner port area Equally space emblers one layer thick Do not pile ember material over one layer thick as this does not enhance the ember appearance or improve the log set performance Fig 8 7 Flames must not impinge touch on logs WARNING Do not use more embers than those supplied with your unit Do not use emb...

Страница 11: ... connecting a wall switch thermostat or remote control use only the top and bottom control valve terminals for attachment of the wire leads do not use center terminal of terminal block Figs 9 and 10 Remote Control Information The remote receiver does not need to be secured to the VFL34R N P base but can be placed along side of the log base assembly larger fireboxes only in a wall mounted switch bo...

Страница 12: ...en smell for gas including near the floor If you smell gas STOP Follow B in the safety information above If you don t smell gas go to the next step 4 Refer to Figure 13 Locate the pilot It is positioned on the burner behind the front log and below the right twig times This will cause a spark at the pilot which will ignite the pilot gas 7 Hold the control knob for 20 seconds to prevent the flame fa...

Страница 13: ...pliance is operating WARNING The glowing ember base and all the logs are manufactured from bonded ceramic fiber This is a commonly used material in industry worldwide In the event of the logs and base being removed care should be taken not to damage the bonded material Intentional misuse of or deliberately fragmenting the material could lead to inhaling fibers and be injurious to health Insure the...

Страница 14: ...e required under normal use Dusting the front grate or the control knob panel may be required occasionally Do not use any cleaning fluids to clean the logs or any other part of the appliance If the flames show any unusual shapes or behavior or if the burner s fail to ignite properly then the burner holes may require cleaning If this occurs contact your nearest dealer to get the appliance serviced ...

Страница 15: ...lace assembly Ignitor cable pinched or broken Free ignitor cable if damaged replace it Ignitor cable not connected to ignitor Connect cable to ignitor 2 Pilot will not stay lit Partially clogged ODS pilot orifice Contact qualified service person or your gas company Corrosion of thermocouple contact Clean thermocouple contact Bad gas valve Replace gas valve Control knob not pressed in long After pi...

Страница 16: ...78439 1 Air Scoop 78445 78445 1 Valve Natural 55463 1 Valve LP Propane 55462 1 Burner Natural 78474 1 Burner LP Propane 78473 1 Pilot Natural OP 78167 1 Pilot LP Propane OP 78169 1 Manifold Tube Split Nut 78456 78456 1 Orifice 31 Natural 78458 1 Orifice 50 LP Propane 78451 1 Tube Flexible Gas Inlet 71598 71598 1 Tube Pilot 3 16 78583 78583 1 Ignitor w Nut Piezo 65180 65180 1 Wire Assembly Rocker S...

Страница 17: ...allation instructions and in compliance with local codes and ordinances The logs must be placed strictly in accor dance with the arrangement described in the installation instructions The Product must be operated and maintained according to the instructions furnished Alteration of the Product in any way is prohibited and voids any and all war ranties Removal of the data plate alters the Products a...

Страница 18: ...rners as well as proper appearance of flames Verify that ceramic fiber and refractory components are properly positioned and secure Rear burner must not contact logs Verify adequate clearance to mantels and other combustibles Demonstrate correct operation of the product to the consumer NOTE LP models must not be operated if fuel tank is less than 1 4 full Observe the consumer operating the product...

Страница 19: ...burners as well as proper appearance of flames Verify that ceramic fiber and refractory components are properly positioned and secure Rear burner must not contact logs Verify adequate clearance to mantels and other combustibles Demonstrate correct operation of the product to the consumer NOTE LP models must not be operated if fuel tank is less than 1 4 full Observe the consumer operating the produ...

Страница 20: ...er your warranty please provide the information indicated on this form and mail it to TEMCO Fireplace Products Attn Warranty Registration 410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 Model ______________________________________ I certify that I have followed all codes and regulations and adhered to the TEMCO installation instructions I have completed the proper installation and startup chec...

Отзывы: