10
78570
If you connect natural gas to an LP gas unit, you may be
unable to ignite the pilot. If the pilot does ignite, the burner
flame on the low setting will be bright blue but only 1/4” to 1/2”
long and most likely lifting off the burner ports. If this is the
case, turn the unit off immediately.
If you connect LP gas to a natural gas unit, the burner flame
on the low setting will be about 6” - 8” long. On the high setting,
the burner flames will be bright yellow and about 10” in length.
Turn the unit off immediately! If the unit is allowed to run in
this condition, substantial amounts of soot will be generated
and emitted into the house.
Log Assembly
Refer to Figures 6, 7 and 8
1. Remove logs from carton and inspect.
2. Rear log should be installed onto rear log supports. Match
up slots on rear of log with the vertical log bracket tabs. (Fig.
6)
3. Place the bottom edge of the large front log between the two
tabs located in the log support channel which centers the log
left to right. (Fig. 6)
4. The two top twigs can then be placed in their designated
positions located with pins on back logs and grooves on the
front log. (Fig. 7)
5. Lava rock from the bag provided should be placed on the
hearth pan area to suit individual appearance preferences.
DO NOT place volcanic ash on burner, pilot or logs.
6. Platinum embers are to be placed only on top of the front
burner port area. Equally space emblers one layer thick.
Do not pile ember material over one layer thick as this
does not enhance the “ember” appearance or improve
the log set performance. (Fig. 8)
7. Flames must not impinge (touch) on logs.
WARNING: Do not use more embers than those supplied with
your unit. Do not use embers other than genuine “Platinum
Embers” supplied by Temco Fireplace Products - Part No.
78037.
When you have completed these steps, compare log positions
with Figure 7. The logs must be positioned as illustrated.
CAUTION: Proper location is critical. When positioning the log
set, make sure that the logs do not interfere with the sides of
the fireplace before securing the chassis.
Fireplace Screen
A fireplace screen must be in place when the appliance
is operating and unless other provisions for combustion air
are made, the screen must have openings for the introduction
of combustion air.
Rear Log Supports
Support
Channel & Tabs
T131
Fig. 6 Match up slots on rear of log with vertical log bracket
tabs.
Fig. 7 Correct log placement.
Rear Log
Right Twig
Left Twig
Front Log
TL106
Platinum Ember
TL107
Fig. 8 Platinum ember placement.
WARNING: Failure to position the parts in accordance
with this diagram or failure to use only parts specifically
approved with this heater may result in property damage
or personal injury. See instruction manual for further