11
76683
Optional Wireless Remote Installation
Two remote control kits are offered. The standard ON/OFF
model is a WRD-I and the thermastatic model is a WRST-K
The remote receiver will be similar to that shown in Figure 12,
letter “B”.
There will be a battery terminal and two wire leads. The remote
receiver does not need to be secured to the PS24R(N,P) base,
but can be placed along side or under the log base assembly.
(Fig. 12)
The enclosed jumper wires can be attached to the receiver
wires by joining the female connectors from the receiver. All
connections should be made as shown in the remote kit
instructions. The jumper wire should be routed behind the cover
plate to the valve. The wires from your receiver can be con-
nected to the two outer terminals on the valve, making sure it is
the two outer terminals and not the center one. (Fig. 14 & 16)
You may now refer to the lighting instructions for use. The log
set should not be modified to accept any other type of remote
control as no guarantee may be make regarding proper
function. Refer to remote manufacturer’s instructions for battery
replacement.
Millivolt Wall Switch Installation
To install your millivolt wall switch, an approved wall box should
be installed in a location suitable to you. The thermostat wire
should be routed from the wall box to the log set and should be
routed underneath the log set and pulled up to the valve's wiring
terminal as shown in. (Fig. 9)
The two wires, letter “A”, should not be removed or changed.
Remove switch wires, Letter B. The two female ends of your
wire can be connected to the two outer connections just below
the screw terminals as shown in Figures 9 & 14.
Now the wall switch can be wired as shown in. (Fig. 10) The
wires can be connected to either poles as they carry only
millivolt current. No ground is used at the wall switch. See the
lighting instructions for the millivolt wall switch on Page 13.
Wall switch must be for millivolt operation.
Do not connect 120 Volts to wall switch.
C
B
A
T114
A Thermopile (Do not remove)
B Switch (OFF/ON)
C Wires from receiver (red &
white) or wires from millivolt
wall
Fig. 9 Control valve terminal block.
Recommended Maximum Lead Length (Double Wire)
When Using Wall Switch or Thermostat
Wire Size
Maximum Length
14 ga.
50’
16 ga.
32’
18 ga.
20’
20 ga.
15’
22 ga.
10’
NOTE: Must be stranded wire.
Fig. 10 Optional wiring to wall switch.
T149
Piezo Pilot Ignitor
Inlet Pressure Check
Manifold
Pressure
Check
HI/LO Flame
Adjustment
Control
Blue Flame (Front Burner) ON/OFF Control
ON/OFF Switch
Main Valve ON/OFF/PILOT Control
T153
Fig. 11 PS24 control panel.
Fig. 12 PS24 burner controls.
A
B
A - Piezo Ignitor
B - Remote Receiver
T154