background image

TEMA TELECOMUNICAZIONI    

                                          

AD630S/630SA VoIP SIP 30W / PoE Horn

 

MAS-AD630S-REV00-Programming manual 

 

 

 

 

                            Page 4 of 24 

 
1.2.  Access to programming 

 
To  program  the  device,  it  is  sufficient  to  use a  normal  browser,  such  as  Explorer,  Firefox,  Chrome  or  other.  The 
user / password to connect with are 

master/master

. Once logged in, it will be possible to change the administration 

password for maximum security of your device, see par. 1.9  
 
Use is very simple and intuitive, the menu for choosing the functions to be programmed is always visible on the left, 
while  the  configuration  mask  active  at  that  time  is  shown  on  the  right.  Any  changes  will  be  confirmed  with  the 

"Save"

  button.  Closing  the  browser  or  changing  the  page  without  selecting  this  button 

will  make  any  changes 

lost

.  

 
As soon as the device is accessed, a mask will be presented which summarizes the general status of the system: 

 

 

 

 

Any  changes  do  not  require  the  device  to  be  restarted  (except  for  changing  the  IP  address  and  updating  the 
software).  
 
The address that appears next to the "Stream" field and the one programmed as # 11 on the Multicast web page 
(see  below).  It  serves only  as  a  reminder  and  facilitates  the identification  of  the  audio  address  assigned  to  each 
horn. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

The programming manual in PDF is also available on the 
web server of

 

the device. 

 

Содержание AD630S

Страница 1: ...evision Date Revision reason Prepared Cecked Approved 0 19 04 2022 First edition MM DP DP FL TEMA TELECOMUNICAZIONI IP COMMUNICATION AND SECURITY COMPANY WWW TEMATLC IT Products for VoIP SIP LAN networking Communications Paging Amplifiers Systems and Audio Applications Zone Announcements Night Ringer Multicast general call Background music Standard SIP call or Emergency call SD memory with pre rec...

Страница 2: ...SCRIMINATES THE NUMBERS TO CALL FOLLOWING THE PRESSURE OF THE CALL KEYS OR THE ACTIVATION OF THE ALARMS 9 NOTE THE AUTOMATIC SETTING CAN ONLY WORK CORRECTLY IF A TIME SERVER IS PROGRAMMED IN THE NETWORK CONFIGURATION WEB PAGE 9 1 7 INPUTS 10 1 8 OUTPUTS 12 1 9 MAINTANCE 13 1 10 MULTICAST 14 1 11 AUTOMATIC ANNOUNCEMENTS 16 YOU CAN UPLOAD A TEXT FILE IN CSV FORMAT THEREFORE EASILY EDITABLE WITH EXCE...

Страница 3: ...nce of a local DHCP server to be able to program one use the appropriate scan program for TEMA devices on the network supplied with it called devicescan tema exe This software will show all the Tema devices present in the LAN with their respective serial numbers MAC address IP address description of the devices By double clicking on the device name it will be possible to manually change the IP add...

Страница 4: ... configuration mask active at that time is shown on the right Any changes will be confirmed with the Save button Closing the browser or changing the page without selecting this button will make any changes lost As soon as the device is accessed a mask will be presented which summarizes the general status of the system Any changes do not require the device to be restarted except for changing the IP...

Страница 5: ... of connection Dynamic DHCP or Static IP Address indicate the IP address you want to assign to AD630S Subnet mask indicate the network mask you want to assign to the AD630S Default gateway indicate the gateway that can allow AD630S to access the internet Primary and Secondary DNS Server Specify the addresses of the two DNS servers that you want to use to resolve the IP addresses Time server indica...

Страница 6: ...d to which the AD630S must connect Port is the number of the SIP port of the PBX with which to forward incoming calls Generally it is the 5060 but some stations use another port Domain enter the domain to which to register inserire Outbound proxy some control panels require that the extension number to be called is followed by the proxy address In most cases this field can be left blank Local SIP ...

Страница 7: ...It is possible to change the customized one from the maintenance web page Test Ring ON Test Ring OFF buttons that activate the ringer for the purpose of testing the sound emitted Increasing volume with this option the volume will start low and will increase due to no response over time until it reaches the maximum volume set in Ringtone volume Relay 1 2 activation it is possible to choose whether ...

Страница 8: ...ts for the user to enter this code If correct the system starts recording the caller s message which will be played when the phone call is hung up It is possible to abort the registration by typing Push to talk allows you to enable the microphone only after pressing a button connected to the programmed input Communication volume sets the volume of the audio played to the external user Possible val...

Страница 9: ...cters Night bands in the case of automatic operation it is possible to insert up to 5 NIGHT setting day bands Outside these ranges the system is in DAY The fields in the table indicate in which time slot the system is in the night Outside these time slots the device is in the day In the example from Monday to Friday the system is in the night until 8 in the morning and then from 17 30 until midnig...

Страница 10: ...ponse Finally in ringer mode it can act as a repeater when activated it behaves as if a call came to the ringer account it would use its programming Inversion indicates whether the activation of the input is to be considered upon closing the contact or upon opening inversion Day night number number to call upon activation of the entrance both day and night Stream when an alarm is triggered after h...

Страница 11: ...arming it is used to prevent the input from reactivating within a certain number of seconds Think for example of a sensor used to give a message to a passing person Silence valid in alarm mode Silence code to interrupt the series of calls Announcement upon activation of the entrance the relevant announcement is issued locally Sending email when the alarm is activated or when the button is pressed ...

Страница 12: ...de 2 On call activated with a conversation in progress until the horn returns to rest 3 Pressing the button pressing any button activates the output for the set time 4 Alarm activation activated for the entire duration of the cycle of any alarm 5 Stream the output is activated when any audio stream is received Activation code relay activation code to be dialed from the internal telephone to the PB...

Страница 13: ...f Alarm Announcement and Ringtone The memory contains default messages for each of the positions the messages can be customized by the user at will as long as the WAV PCM 8 kHz 16 bit mono format is used and that each message does not exceed 60sec in length In this same screen it is also possible to save or restore the configuration change the access password or change the firmware of the device ...

Страница 14: ...iority You can choose only 1 among them and it allows you to choose for example the music you want to listen to if several audio streams are transmitted on the network at the same time The last 7 on the other hand are priority They can interrupt the audio of the first 9 and in turn be interrupted by a higher priority stream For example if I am playing a music channel it will be interrupted by a se...

Страница 15: ...grammable channel and broadcasts the same announcement on all SLAVE loudspeakers enabled to receive the Multicast channel programmed in the Master unit By inserting an AD615 SIP device in the scenario it will be possible to further diversify the zones since the AD615 SIP answer allows you to select from your telephone up to 16 Multicast channels Zones where to transmit an announcement through the ...

Страница 16: ...the number of seconds set It is also possible to manually activate the message with the Activate immediately button or stop playback with the Stop button If you use only the manual activation mode you do not need to indicate the start time The message reproduced is one of the 9 alarm announcement messages found in the Maintenance section Periodic activation from table if this function is activated...

Страница 17: ...be played at 09 00 message 2 at 12 30 and message 3 at 17 30 Streaming Finally it is possible to play the indicated messages not to the local speaker but in streaming to a multicast address To do this it is sufficient to insert after the message number the letter S followed by the multicast channel number programmed in the Multicast transmission mask For example 1S2 means stream message 1 to the p...

Страница 18: ...decide to send an email with a positive outcome and in this case you must receive an email certifying the correct functioning of the device every day or simulate an alarm in the event of a negative outcome in which case the device will follow the programming of the relative alarm The tones are designed not to be annoying but since they are still audible it is advisable to perform the self test at ...

Страница 19: ... To identify small configuration problems it is possible to have a textual diagnostic relating to the activity of the VoIP channel of the device It is also possible to perform a low level network trace with the dump button A file in pcap format readable with the Wireshark program will be created freely downloadable from the web ...

Страница 20: ...personnel operate verifying that no cable is under voltage also strictly comply with the instructions of the voltage and current values for the power supplies and other parts of the system Follow the instructions below in the drawing block for the correct electrical connection of the system On the following page there is the detail of each terminal shown Connector for external buttons P1 and P2 P1...

Страница 21: ... NO contact normally open 4 K2 CC Terminal block of the K2 relay CC contact central contact contact load max 30V 1 5A 3 K2 NA Terminal block of the K2 relay NO contact normally open 2 GND Terminal block referred to the negative of the system power supply for the alarm contact 1 ING1 Terminal block for the detection of the external alarm contact 4 pin removable terminal block connector inserted to ...

Страница 22: ...e same design to increase power directionality extend the area served even in different rooms separated by walls in order to reduce the cost of the plant LAN POE SP SP AD630S AD330 30T Satellitespeaker AD330 30T Satellitespeaker LAN POE SP SP AD630S AD330 30T Satellitespeaker Correspondence cables AWG mm2 AWG20 0 518 mm2 resistance 33 31 Ohm Km AWG19 0 653 mm2 resistance 26 42 Ohm Km AWG18 0 823 m...

Страница 23: ...sockets 25 12 5 6 25 3 12 W response 300Hz 7KHz Dim Diam 240 x 290 mm AD335 06TP Wall Speaker 6W 8Ohm Transf 100V sockets 6 3 1 5 W response 180Hz 16KHz Dim 218 x 216 x 120 mm AD334 20TP Vandal proof Projector 20W with transf 100V outdoor sockets 20 10 5 W IP65 response 150Hz 15KHz Dim Diam 180 x 145 mm weight 2 4kg grey color AD337 06TP Oval wall speaker 6W 8Ohm with transf 100V sockets 6 3 1 5W ...

Страница 24: ...TEMA TELECOMUNICAZIONI AD630S 630SA VoIP SIP 30W PoE Horn MAS AD630S REV00 Programming manual Page 24 of 24 Notes ...

Отзывы: