TEMA TELECOMUNICAZIONI
AD630S/630SA VoIP SIP 30W / PoE Horn
MAS-AD630S-REV00-Programming manual
Page 11 of 24
•
Separation:
valid in alarm mode. Separation, in seconds, between one call attempt and the next.
•
Delay:
valid in alarm mode. Activation delay in seconds. It is used to cover any short-term events for which
an alarm is not desired.
•
Waiting for rearming:
it is used to prevent the input from reactivating within a certain number of seconds.
Think for example of a sensor used to give a message to a passing person.
•
Silence:
valid in alarm mode. Silence code to interrupt the series of calls.
•
Announcement:
upon activation of the entrance, the relevant announcement is issued locally.
•
Sending email:
when the alarm is activated or when the button is pressed, it is possible to send an email
with a predefined text to the specified address. The sending credentials are those programmed in the
"Network" page.