![Tema Telecomunicazioni AA-539 Скачать руководство пользователя страница 41](http://html.mh-extra.com/html/tema-telecomunicazioni/aa-539/aa-539_technical-manual-and-installation-manual_1085252041.webp)
TEMA TELECOMUNICAZIONI SRL
Doorphone AA-539
MAS-AA539-REV02EN
Page 41 of 57
9.4.
Parameters table
In the following table are described the system parameters. All the values will be retained even if the system is
powered off.
Parameter
Name
Description
Range = possible values
Default
Enter your
settings
153 #
Expansion type
Set AA-539 expansion used
0 = no expansion
2 = expansion model AA-539K
Range: 1 digit, values 0-2
0
118 #
Operation mode of
buttons
Set the operating mode when the button is pressed.
0 = DAY/NIGHT mode (see parameters 121/122)
1 = GROUP mode
2 = DAY/NIGHT mode with repetition call
Range: 1 digit, values 0-2
0
101 #
Max conversation
time
Maximum call duration time in seconds, for inbound and
outbound call.
Range: max 4 digits, values 10 -9999
60
110 #
Telephone number
button in
DAY mode
Telephone number associated to the button in DAY mode or
first number in Group mode.
Range: max 16 digits, values 0-9, *
* =pause of 0.5 seconds
9
114 #
Telephone number
button in
NIGHT mode
Telephone number associated to the button in NIGHT mode or
second number in Group mode.
Range: max 16 digits, values 0-9, *
* =pause of 0.5 seconds
9
220 #
Supervisor Number
Number of the supervisor. The supervisor is the person called
from AA-539 when it is programmed to work in Group mode
(parameter 118 value 1). This number will be called if it is not
received a reply from the numbers associated with the Day
and Night mode with the confirmation code response
(parameter 123). This number may be associated to a
guardian or to an available person that can be available.
Range: max 16 digits, values 0-9, *
* =pause of 0.5 seconds
-
119 #
Call closing
command
Command to hang up the current conversation to force the
system in standby mode. It may be equal to the open relay1
code (parameter 120).
Range: max 3 digits, values 0-999, #, *
#0
127 #
Conversation time
extension
Command to keep alive the current conversation resetting the
max conversation time at the value of parameter 101.
Range: 3 max digits, values 000-999, #, *
#5
123 #
Answer code
In the operation mode GROUP and D/N with repetition, it is
possible to signal to the system the successful reply from the
called telephone, by dialing the number programmed here
immediately after answering the call.
Range: max 1 digit, value 0-9
1
129 #
Time between call
attempts
Defines the minimum time (in seconds) between two
subsequent calls.
Range : max 3 digits, values 0-999
5
155 #
Answering time
Time in seconds within which AA-539 must receive the answer
code (stored in parameter 123).
Range : max 2 digits, values 0-99
30
157 #
Number of call
cycles
Indicates the number of call cycles to be carried out according
with parameter 118.
Range : max 2 digits, values 0-99
3
149 #
Speed Dialing
mode
Only for models with AA-539K expansion numeric keypad.
Allows to associate to the 0-9 keys of the keyboard up to 10
preprogrammed numbers to call (if set to 1) or allows to
associate the 000-999 Speed Dial numbers of the keyboard up
to 1000 preprogrammed numbers to call (if set to 2) .
0 = Speed Dial mode disabled
1 = Speed Dial mode enabled
2 = Super Speed Dial mode enabled
Range: 1 digit, values 0-1-2
0