ABOUT THIS MANUAL 

This manual assumes that you have basic security system installation skills such as 
measuring voltages, stripping wire, properly connecting wires together, connecting wires to 
terminals, and checking phone lines.  It also assumes that you have a familiarity with the 
proper installation and programming tasks related to various control communicator panels. 
 
The material and instructions covered in this manual have been carefully checked for 
accuracy and are presumed to be reliable.  However, Telular assumes no responsibility for 
inaccuracies and reserves the right to modify and revise this manual without notice. 
 
It is our goal at Telular to always supply accurate and reliable documentation.  If a 
discrepancy is found in this documentation, please mail or fax a photocopy of the corrected 
material to: 
 

Telular Security Products 
Technical Services Department 
420 Thornton Road, Suite 109 
Lithia Springs, GA 30122 
Fax: 678-945-1651 
 

© 2006 Telular Corporation.  Lithia Springs, GA U.S.A.  All rights reserved. 
 
 

FCC NOTICES 

EXPOSURE TO RADIO FREQUENCY ENERGY 

In 1991, the Institute of Electrical and Electronics Engineers (IEEE), and in 1992, the American National 
Standards Institute (ANSI), updated the 1982 ANSI Standard for safety levels with respect to human 
exposure to RF energy.  Over 120 scientists, engineers and physicians from universities, government health 
agencies and industry, after reviewing the available body of research, developed this updated Standard.  In 
March 1993, the U.S. Federal Communications Commission (FCC) proposed the adoption of this updated 
Standard. 
 
The design of your Telular 

Telguard 

complies with this updated Standard.  Of course, if you want to limit RF 

exposure even further than the updated ANSI Standard, you may choose to install the unit in a manner that 
locates its antenna at an even greater distance from the general public than is recommended as a minimum 
by the standard. 
 
To insure compliance with the standard, when selecting a mounting location for your 

Telguard 

do not mount 

it (or its associated antenna) in an area where the general public could reasonably be within 8 inches (20 
centimeters) of the antenna. 
 

EFFICIENT OPERATION 

Do not operate your Telular product when holding the antenna.  Be sure to mount the unit such that its 
antenna is a minimum of eight (8) inches (20 centimeters) is maintained from the general public. 

 
For the best service quality, keep the antenna free from obstructions and point the antenna straight up. 
 

Содержание TELGUARD DIGITAL TG-1

Страница 1: ...ENTIAL For use by TELGUARD customers only Distribution to others strictly prohibited Revised January 9 2006 TELGUARD is a registered trademark of Telular Corporation Products are protected under one o...

Страница 2: ...ard model TG1G0001 is UL Listed for Household Fire systems and Household Burglary systems This means that the TG1G0001 may be used in Household Burglary systems Household Fire systems or combined Hous...

Страница 3: ...ectronics Engineers IEEE and in 1992 the American National Standards Institute ANSI updated the 1982 ANSI Standard for safety levels with respect to human exposure to RF energy Over 120 scientists eng...

Страница 4: ...en in any area with a potentially explosive atmosphere It is rare but your Telguard Digital or its accessories could generate sparks Sparks in such areas could cause an explosion or fire resulting in...

Страница 5: ...UND You agree to accept sole responsibility for any misuse of the Product by you and in addition any negligent or illegal act or omission of your or your agents contractors servants employees or other...

Страница 6: ...ILURE CONDITION RFC 2 2 4 COMPLETE POWER SUPERVISION 2 2 4 1 LOW MISSING BATTERY CONDITION LBC 2 2 4 2 AC FAILURE CONDITION ACFC 2 2 4 3 DIAL TONE FAILURE DTF 2 2 4 4 CATASTROPHIC FAILURE CF 2 2 5 TEL...

Страница 7: ...NAL TRANSMISSIONS OVER CELLULAR 10 5 4 STEP 4 CONNECT SUPERVISORY TRIP OUTPUTS 10 5 4 1 DECIDE ON A STC TRIP OUTPUT STRATEGY 11 5 4 2 CHECK TELGUARD SUPERVISORY TRIP TO C C 11 5 4 2 1 REPROGRAM C C TO...

Страница 8: ...uard has its own internal power supply battery charger All cellular monitoring and supervisory functions are built in No extra modules are required The Listed equipment at the Telular Communication Ce...

Страница 9: ...the STC trip output restores after 60 seconds 2 4 3 Dial Tone Failure DTF The Telguard continuously monitors the 30V sully circuit that provides dial tone to the C C A Dial Tone Failure DTF is declar...

Страница 10: ...e battery and AC power The terminal strip can accommodate solid or stranded wire sizes from 14 to 22 gauge 2 6 1 Programmable Supervisory Trip Output STC Relay The Telguard Digital TG 1 has one superv...

Страница 11: ...transmit signals over cellular LED 4 Acknowledgement Solid On Telguard TG 1 waiting for acknowledgement from Communication Center Off Idle state Red Flashing When flashing with LED 1 unit has failed...

Страница 12: ...he customer account unit location and system test plan information 3 1 DEALER ACCOUNT ESTABLISHMENT Prior to activation of any Telguard unit a Dealer Account must be established Once the Dealer Accoun...

Страница 13: ...ating under 3 Confirmation from the Telular Communications Center that the Telguard Digital unit is ready for installation and registration Registration is the process of establishing communications f...

Страница 14: ...apply power to Telguard attach battery leads to battery terminals noting polarity Connect the Telguard AC power transformer see A3 2 for acceptable UL Listed transformers to AC terminals using strand...

Страница 15: ...on LED 3 2 off 100 dBm 2 LED 5 4 on LED 3 slow flash LED 2 off 90 dBm Minimum signal strength required 3 LED 5 3 on LED 2 off 80 dBm 3 LED 5 3 on LED 2 slow flash 70 dBm 4 LED 5 2 on 60 dBm Note LED 1...

Страница 16: ...NG 2 FLASH LBC LOW BATTERY AND OR BATTERY CHARGER FAIL 3 FLASH N A 4 FLASH NSC NO SERVICE 5 FLASH RFC RADIO FAILURE 6 FLASH DTF DIAL TONE FAIL 5 3 1 Setup Programming the Operating Parameters in the T...

Страница 17: ...899 will return unit to factory default settings 5 3 3 Verify Alarm Signal Transmissions over Cellular Trip several alarms on the C C and verify that the central station received them by calling the...

Страница 18: ...s missing Check to see that the C C transmits the STC trouble code over cellular to the central station Reconnect the battery and check during the next 60 seconds to see that the STC LED goes off indi...

Страница 19: ...OUBLE STC See Table LED 1 GREEN REGISTRATION See Table SYSTEM TROUBLE STC LED 2 1 FLASH AC LOW MISSING 2 FLASH LBC LOW BATTERY 3 FLASH Not Used 4 FLASH NSC NO SERVICE 5 FLASH RFC RADIO FAILURE 6 FLASH...

Страница 20: ...grammed supervisory trouble code AC Power Fail ACFC AC failure detected at 102 VAC Low Missing Battery Condition LBC due to Low Battery detected at 11 6 VDC Radio Communications Failure RFC due to Fai...

Страница 21: ...or TG 1 LED 3 MODE Yellow Fast Flash C C off hook to transmit signals over cellular LED 4 Acknowledgement Solid ON Telguard TG 1 waiting for acknowledgement from Communication Center OFF Idle state Re...

Страница 22: ...turn unit for repair on RMA Not Active for Cellular alarm Transmission Yes LED 5 off Yes None Telguard will not function until operating parameters are downloaded to the Telular Communication Center S...

Страница 23: ...56034002 1 9 2006 16 2006 Telular Corporation A2 1 ACTIVATION FORM...

Страница 24: ...ber S189480032 GlobTek part number WA1E800J00 N GTGTAB A3 3 DIGITAL CELLULAR RADIO The Telguard TG 1 radio supports GSM GPRS cellular protocol It is equipped with an integrated radio transceiver confo...

Страница 25: ...e antenna TG1G0001 is UL Listed for the following o UL Household Burglary o UL Household Fire o UL Household Burg Fire Combination General Accessories ACD 12 12 feet of antenna cable and mounting brac...

Отзывы: