Telular TELGUARD DIGITAL TG-1 Скачать руководство пользователя страница 17

56034002  1/9/2006 

10

                            

 

© 2006 Telular Corporation

 

5.3.2  Complete the Telguard Programming Data Sheet    

Fill out the following 

Telguard Programming Data Sheet

.  The completed data sheet enables you to 

properly install and test the Telguard as well as provide a valuable aid to future troubleshooting if it 
becomes necessary.  Detach and retain this data sheet in your customer account file for future 
reference. The Telguard default setup is pre-programmed at the factory.  Default setup values are 
listed

 

and highlighted in "

bold

" type. 

 

MEMORY 

LOCATION 

FIELD 

 DEFAULT 

VALUE 

SETTING 

833 

C/C Reporting Format 

08 

08 = Contact ID 

 

851 

STC Trip Output 
Reporting 

Normally Closed 

27 

Enter the 

SUM TOTAL

 of the events that you wish to trip the  

STC relay by 

ADDING

 the corresponding values:  

00 = STC Trip Input Not Used 

01 = AC Failure     

04 = not used

       16 = RFC 

02 = Low Battery   08 = NSC             

31 = All 

852 

STC Trip Delay for NSC 

1 1=30 

Seconds

     2=60 Seconds

 

861 

CFC Number of Events 

0 = disabled        

2 = 4 attempts

 

1 = 2 attempts      3 = 8 attempts 

862 

CFC between Events 

1 = 30 seconds    

3 = 70 seconds   5 = 90 seconds

 

2 = 60 seconds     4 = 80 seconds    6 = 99 seconds 

864 

RFC Number of Attempts 

0=Disabled          3 = 3 Attempts    6 = 6 Attempts 
1=1 Attempts       4 = 4 Attempts   7 = 7 Attempts 

2=2 Attempts

      5 = 5 Attempts   8 = 8 Attempts 

867 

Standby Battery Size 
 

0 = No Battery      2 = 1.2 ah           4 = 7 ah 
1 = 0.8 ah             

3 = 4 ah 

872 

AC Failure Delay 

02 

0-24 hours, 

default = 2 hours

 

899 

Factory Default Unit 

 

Accessing 899 will return unit to factory default settings 

 

5.3.3  Verify Alarm Signal Transmissions over Cellular    

Trip several alarms on the C/C and verify that the central station received them by calling the central 
station operator.  Use a lineman's butt-set in 

MONITOR MODE

 and connected to Telguard's "T" and "R" 

test pins to "listen" to communications between the C/C and Telguard.  The ACK LED will come on solid 
while waiting for an acknowledgement.  

 

If you are having problems getting reliable alarm signal transmissions, additional adjustments may be 
necessary. 

♦ 

Recheck signal strength.  You need 

RSSI =

 

 

(TWO LEDS ON SOLID AND THE THIRD LED 

FLASHING)

 for adequate signal strength.  Also, check antenna connector and make sure it is seated 

correctly. 

♦ 

Call Telular Technical Service, 1-800-229-2326 extension 9

, and request the Telular 

Communication Center operator to check the Telguard programming configuration for proper 
operation and

 proper communications format

.   

 

5.4 S

TEP 

4: C

ONNECT 

S

UPERVISORY 

T

RIP 

O

UTPUTS 

 

Connect and test the supervisory trip outputs to the C/C.  

 

Activation of a local alarm or strobe light may be desirable when a trip is declared.  The STC trip output can be 
used directly to activate a local signaling device, provided that the trip output is not needed to trip the host 
control/communicator at the same time.  If both a local signal and a control trip input is required, then external 
relays are needed to provide additional uncommitted contacts. 
 
UL Listed installation of the TG-1 will at a minimum have the trip output to the host C/C to indicate low A/C 
(ACFC) and low battery (LBC) conditions.  

Содержание TELGUARD DIGITAL TG-1

Страница 1: ...ENTIAL For use by TELGUARD customers only Distribution to others strictly prohibited Revised January 9 2006 TELGUARD is a registered trademark of Telular Corporation Products are protected under one o...

Страница 2: ...ard model TG1G0001 is UL Listed for Household Fire systems and Household Burglary systems This means that the TG1G0001 may be used in Household Burglary systems Household Fire systems or combined Hous...

Страница 3: ...ectronics Engineers IEEE and in 1992 the American National Standards Institute ANSI updated the 1982 ANSI Standard for safety levels with respect to human exposure to RF energy Over 120 scientists eng...

Страница 4: ...en in any area with a potentially explosive atmosphere It is rare but your Telguard Digital or its accessories could generate sparks Sparks in such areas could cause an explosion or fire resulting in...

Страница 5: ...UND You agree to accept sole responsibility for any misuse of the Product by you and in addition any negligent or illegal act or omission of your or your agents contractors servants employees or other...

Страница 6: ...ILURE CONDITION RFC 2 2 4 COMPLETE POWER SUPERVISION 2 2 4 1 LOW MISSING BATTERY CONDITION LBC 2 2 4 2 AC FAILURE CONDITION ACFC 2 2 4 3 DIAL TONE FAILURE DTF 2 2 4 4 CATASTROPHIC FAILURE CF 2 2 5 TEL...

Страница 7: ...NAL TRANSMISSIONS OVER CELLULAR 10 5 4 STEP 4 CONNECT SUPERVISORY TRIP OUTPUTS 10 5 4 1 DECIDE ON A STC TRIP OUTPUT STRATEGY 11 5 4 2 CHECK TELGUARD SUPERVISORY TRIP TO C C 11 5 4 2 1 REPROGRAM C C TO...

Страница 8: ...uard has its own internal power supply battery charger All cellular monitoring and supervisory functions are built in No extra modules are required The Listed equipment at the Telular Communication Ce...

Страница 9: ...the STC trip output restores after 60 seconds 2 4 3 Dial Tone Failure DTF The Telguard continuously monitors the 30V sully circuit that provides dial tone to the C C A Dial Tone Failure DTF is declar...

Страница 10: ...e battery and AC power The terminal strip can accommodate solid or stranded wire sizes from 14 to 22 gauge 2 6 1 Programmable Supervisory Trip Output STC Relay The Telguard Digital TG 1 has one superv...

Страница 11: ...transmit signals over cellular LED 4 Acknowledgement Solid On Telguard TG 1 waiting for acknowledgement from Communication Center Off Idle state Red Flashing When flashing with LED 1 unit has failed...

Страница 12: ...he customer account unit location and system test plan information 3 1 DEALER ACCOUNT ESTABLISHMENT Prior to activation of any Telguard unit a Dealer Account must be established Once the Dealer Accoun...

Страница 13: ...ating under 3 Confirmation from the Telular Communications Center that the Telguard Digital unit is ready for installation and registration Registration is the process of establishing communications f...

Страница 14: ...apply power to Telguard attach battery leads to battery terminals noting polarity Connect the Telguard AC power transformer see A3 2 for acceptable UL Listed transformers to AC terminals using strand...

Страница 15: ...on LED 3 2 off 100 dBm 2 LED 5 4 on LED 3 slow flash LED 2 off 90 dBm Minimum signal strength required 3 LED 5 3 on LED 2 off 80 dBm 3 LED 5 3 on LED 2 slow flash 70 dBm 4 LED 5 2 on 60 dBm Note LED 1...

Страница 16: ...NG 2 FLASH LBC LOW BATTERY AND OR BATTERY CHARGER FAIL 3 FLASH N A 4 FLASH NSC NO SERVICE 5 FLASH RFC RADIO FAILURE 6 FLASH DTF DIAL TONE FAIL 5 3 1 Setup Programming the Operating Parameters in the T...

Страница 17: ...899 will return unit to factory default settings 5 3 3 Verify Alarm Signal Transmissions over Cellular Trip several alarms on the C C and verify that the central station received them by calling the...

Страница 18: ...s missing Check to see that the C C transmits the STC trouble code over cellular to the central station Reconnect the battery and check during the next 60 seconds to see that the STC LED goes off indi...

Страница 19: ...OUBLE STC See Table LED 1 GREEN REGISTRATION See Table SYSTEM TROUBLE STC LED 2 1 FLASH AC LOW MISSING 2 FLASH LBC LOW BATTERY 3 FLASH Not Used 4 FLASH NSC NO SERVICE 5 FLASH RFC RADIO FAILURE 6 FLASH...

Страница 20: ...grammed supervisory trouble code AC Power Fail ACFC AC failure detected at 102 VAC Low Missing Battery Condition LBC due to Low Battery detected at 11 6 VDC Radio Communications Failure RFC due to Fai...

Страница 21: ...or TG 1 LED 3 MODE Yellow Fast Flash C C off hook to transmit signals over cellular LED 4 Acknowledgement Solid ON Telguard TG 1 waiting for acknowledgement from Communication Center OFF Idle state Re...

Страница 22: ...turn unit for repair on RMA Not Active for Cellular alarm Transmission Yes LED 5 off Yes None Telguard will not function until operating parameters are downloaded to the Telular Communication Center S...

Страница 23: ...56034002 1 9 2006 16 2006 Telular Corporation A2 1 ACTIVATION FORM...

Страница 24: ...ber S189480032 GlobTek part number WA1E800J00 N GTGTAB A3 3 DIGITAL CELLULAR RADIO The Telguard TG 1 radio supports GSM GPRS cellular protocol It is equipped with an integrated radio transceiver confo...

Страница 25: ...e antenna TG1G0001 is UL Listed for the following o UL Household Burglary o UL Household Fire o UL Household Burg Fire Combination General Accessories ACD 12 12 feet of antenna cable and mounting brac...