Telular TELGUARD DIGITAL TG-1 Скачать руководство пользователя страница 20

56034002  1/9/2006 

13

                            

 

© 2006 Telular Corporation

 

 

A1.2 J

ACK AND 

P

IN 

A

SSIGNMENTS

 

 

Jack 

Designation

 

Connects 

To  

Pin  

Assignment 

 

Function 

Status LED 

Reference 

 

J7 

C/C Digital 

Dialer 

 

Digital Dialer 

input/output 
of host C/C. 

 

 

1 = Brown R1 
2 = Gray  
4 = Red R (Ring) 
5 = Green T (Tip) 
7 = Blue  
8 = White T1 

 
Connects C/C digital 
dialer input/output 
through unit.  
 

 

MODE LED

 will flash 

when C/C is 
communicating over 
cellular 

 

 
 
 

A1.3 T

ERMINAL 

S

TRIP 

P

IN 

A

SSIGNMENTS

 

Terminal 

Strip Pin 

Definition 

Connects 

To 

Function 

Status LED 

Reference 

 
 
 

1 STC 
 
2 STC 
 
 

 

 
 
 
 
 
 

 
 
 

Supervisory 
Relay Trip 
output for 
programmable 
trouble 
conditions. 

Normally closed

 

 
 
 
 

 
 
 
24-hour trip 
zone input on 
host C/C. 
 
 
 
 
 
 
 
 
 
 

 
Enables transmission of programmed supervisory 
trouble code: 
 

• 

AC Power Fail  (ACFC).

   

AC failure detected at 102 VAC. 

 
 

• 

Low/Missing Battery Condition (LBC) 

due to: 

Low Battery detected at 11.6 VDC. 

 

• 

Radio Communications Failure (RFC) 

due to:  

Failure to receive Ack after 3 attempts.

 

 

• 

Loss of Telguard Dial Tone Voltage (DTF)

 

due to: Improper dial tone voltage.   

 20 VDC.

 

 

• 

No Service Condition (NSC) 

due to: 

Received Signal Strength 

 -114 dBm. 

 

When fault condition 

occurs: 

 

AC Power LED OFF 

STC LED Flashes 1 

time. 

 

STC LED Flashes 2 

times. 

 

STC LED Flashes 5 

times. 

 

STC LED Flashes 6 

times. 

 

STC LED Flashes 4 

times. 

 

3 NC 
4 NC 

No connection 

 

 

 

5   - Battery 
6   +Battery

 

12V Backup 
battery Input 

 

 

 

8   AC 
9   AC

 

AC power 
input. 
12 VAC, 10VA.

 

120 VAC 
60Hz un-
switched 
circuit. 

 
Provides primary operational power to Telguard and 
battery charging circuit. 

AC Power LED ON 

when AC is normal. 

AC power LED OFF 

And  

STC LED Flashes 1 
time

 when AC is low 

Содержание TELGUARD DIGITAL TG-1

Страница 1: ...ENTIAL For use by TELGUARD customers only Distribution to others strictly prohibited Revised January 9 2006 TELGUARD is a registered trademark of Telular Corporation Products are protected under one o...

Страница 2: ...ard model TG1G0001 is UL Listed for Household Fire systems and Household Burglary systems This means that the TG1G0001 may be used in Household Burglary systems Household Fire systems or combined Hous...

Страница 3: ...ectronics Engineers IEEE and in 1992 the American National Standards Institute ANSI updated the 1982 ANSI Standard for safety levels with respect to human exposure to RF energy Over 120 scientists eng...

Страница 4: ...en in any area with a potentially explosive atmosphere It is rare but your Telguard Digital or its accessories could generate sparks Sparks in such areas could cause an explosion or fire resulting in...

Страница 5: ...UND You agree to accept sole responsibility for any misuse of the Product by you and in addition any negligent or illegal act or omission of your or your agents contractors servants employees or other...

Страница 6: ...ILURE CONDITION RFC 2 2 4 COMPLETE POWER SUPERVISION 2 2 4 1 LOW MISSING BATTERY CONDITION LBC 2 2 4 2 AC FAILURE CONDITION ACFC 2 2 4 3 DIAL TONE FAILURE DTF 2 2 4 4 CATASTROPHIC FAILURE CF 2 2 5 TEL...

Страница 7: ...NAL TRANSMISSIONS OVER CELLULAR 10 5 4 STEP 4 CONNECT SUPERVISORY TRIP OUTPUTS 10 5 4 1 DECIDE ON A STC TRIP OUTPUT STRATEGY 11 5 4 2 CHECK TELGUARD SUPERVISORY TRIP TO C C 11 5 4 2 1 REPROGRAM C C TO...

Страница 8: ...uard has its own internal power supply battery charger All cellular monitoring and supervisory functions are built in No extra modules are required The Listed equipment at the Telular Communication Ce...

Страница 9: ...the STC trip output restores after 60 seconds 2 4 3 Dial Tone Failure DTF The Telguard continuously monitors the 30V sully circuit that provides dial tone to the C C A Dial Tone Failure DTF is declar...

Страница 10: ...e battery and AC power The terminal strip can accommodate solid or stranded wire sizes from 14 to 22 gauge 2 6 1 Programmable Supervisory Trip Output STC Relay The Telguard Digital TG 1 has one superv...

Страница 11: ...transmit signals over cellular LED 4 Acknowledgement Solid On Telguard TG 1 waiting for acknowledgement from Communication Center Off Idle state Red Flashing When flashing with LED 1 unit has failed...

Страница 12: ...he customer account unit location and system test plan information 3 1 DEALER ACCOUNT ESTABLISHMENT Prior to activation of any Telguard unit a Dealer Account must be established Once the Dealer Accoun...

Страница 13: ...ating under 3 Confirmation from the Telular Communications Center that the Telguard Digital unit is ready for installation and registration Registration is the process of establishing communications f...

Страница 14: ...apply power to Telguard attach battery leads to battery terminals noting polarity Connect the Telguard AC power transformer see A3 2 for acceptable UL Listed transformers to AC terminals using strand...

Страница 15: ...on LED 3 2 off 100 dBm 2 LED 5 4 on LED 3 slow flash LED 2 off 90 dBm Minimum signal strength required 3 LED 5 3 on LED 2 off 80 dBm 3 LED 5 3 on LED 2 slow flash 70 dBm 4 LED 5 2 on 60 dBm Note LED 1...

Страница 16: ...NG 2 FLASH LBC LOW BATTERY AND OR BATTERY CHARGER FAIL 3 FLASH N A 4 FLASH NSC NO SERVICE 5 FLASH RFC RADIO FAILURE 6 FLASH DTF DIAL TONE FAIL 5 3 1 Setup Programming the Operating Parameters in the T...

Страница 17: ...899 will return unit to factory default settings 5 3 3 Verify Alarm Signal Transmissions over Cellular Trip several alarms on the C C and verify that the central station received them by calling the...

Страница 18: ...s missing Check to see that the C C transmits the STC trouble code over cellular to the central station Reconnect the battery and check during the next 60 seconds to see that the STC LED goes off indi...

Страница 19: ...OUBLE STC See Table LED 1 GREEN REGISTRATION See Table SYSTEM TROUBLE STC LED 2 1 FLASH AC LOW MISSING 2 FLASH LBC LOW BATTERY 3 FLASH Not Used 4 FLASH NSC NO SERVICE 5 FLASH RFC RADIO FAILURE 6 FLASH...

Страница 20: ...grammed supervisory trouble code AC Power Fail ACFC AC failure detected at 102 VAC Low Missing Battery Condition LBC due to Low Battery detected at 11 6 VDC Radio Communications Failure RFC due to Fai...

Страница 21: ...or TG 1 LED 3 MODE Yellow Fast Flash C C off hook to transmit signals over cellular LED 4 Acknowledgement Solid ON Telguard TG 1 waiting for acknowledgement from Communication Center OFF Idle state Re...

Страница 22: ...turn unit for repair on RMA Not Active for Cellular alarm Transmission Yes LED 5 off Yes None Telguard will not function until operating parameters are downloaded to the Telular Communication Center S...

Страница 23: ...56034002 1 9 2006 16 2006 Telular Corporation A2 1 ACTIVATION FORM...

Страница 24: ...ber S189480032 GlobTek part number WA1E800J00 N GTGTAB A3 3 DIGITAL CELLULAR RADIO The Telguard TG 1 radio supports GSM GPRS cellular protocol It is equipped with an integrated radio transceiver confo...

Страница 25: ...e antenna TG1G0001 is UL Listed for the following o UL Household Burglary o UL Household Fire o UL Household Burg Fire Combination General Accessories ACD 12 12 feet of antenna cable and mounting brac...

Отзывы: