Phonecell SX4D Programming - continued
SX4D GSM 900 • SX4D GSM 1800
33
U
SER
M
ANUAL
Enter Periodic Self Test Time Option
The following key sequence is used to program periodic self test time
interval:
Label: SELF TEST TIME
Data: <self-test interval>
The self-test interval is programmed in 1-minute increments from
1
to
65,535
. A value of
0
disables periodic self test. If the value is not between 0
and 65,535, inclusive, it will be considered invalid. The factory default is
180
.
Enter Dial Tone Type Selection Option
The following key sequence is used to select the dial tone type option:
Label: DIAL TONE TYPE
Data: <dial tone frequency>
The dial tone frequency selection option value is set to
0
to select the North
American dial tone frequency pair (350 + 440 Hz); set to
1
to select
European dial tone frequency (425 Hz). If the dial tone frequency selection
option value is neither 0 nor 1, it is considered invalid and the Phonecell will
not update or store this value; the currently stored value will remain. The
factory default is
1
.
Enter In-Call DTMF Signaling Option
The following key sequence is used to select if in-call DTMF signaling
is enabled:
Label: IN CALL DTMF
Data: <in-call DTMF signaling enabled>
The in-call DTMF signaling value is set to
0
for disabled or
1
for
enabled. If the in-call DTMF signaling value is neither 0 nor 1, it is con-
sidered invalid. The factory default is
1
.
Enter Mobile Equipment Personalization for SIM
The following key sequence is used to enter the MEP option:
Label: MEP: SIM
Data: <MEP Operation>
*
<MEP Password>
MEP operation value is set to
0
to deactivate personalization;
1
to activate
personalization;
2
to disable personalization;
3
is reserved for future use. If
the MEP operation value is not in the range 0 to 3, it is considered invalid.
The MEP password is a special value available only to authorized personnel.
The factory default is set to
0
deactivated.
Enter Mobile Equipment Personalization for Network
The following key sequence is used to enter the MEP option:
Label: MEP: NETWORK
Data: <MEP Operation>
*
<MEP Password>
MEP operation value is set to
0
to deactivate personalization;
1
to activate
personalization;
2
to disable personalization;
3
is reserved for future use. If
the MEP operation value is not in the range 0 to 3, it is considered invalid.
The MEP password is a special value available only to authorized personnel.
The factory default is set to
0
deactivated.