U

SER

M

ANUAL

Phonecell SX4D Programming - continued

Exit Programming Mode

The programming mode can be exited by any one of the following:

1. Go “off-hook” (pick up handset)

2. Failure to enter the correct password three times (technician mode only)

3. Failure to enter any digit within two minutes.

The 

PM

(

Programming Mode)

icon is then turned off, returning the Phonecell

SX4D to the 

Normal Mode

.

Phonecell SX4D User-Programming Commands

The following commands are displayed when in the user programming mode. An
<

entered value

> is comprised of the digits 0 through 9.

How to Enter Call Alert Volume 

The following key sequence is used to enter the volume of the call alert:

Label: CALL ALERT VOL
Data: <volume>

The volume value is set to 

0

for off; 

1

for low; and 

2

for high. If the 

volume value is greater than 2, it is considered invalid. The factory
default is 

2

.

Enter Auto Send Delay 

The following key sequence is used to enter the auto send delay: 

Label: AUTO SEND DELAY
Data: <delay>

If the delay is not in the range of 

2

to 

20

seconds, it is considered

invalid. The factory default is 

3

.

Enter RSSI Display Type Option 

The following key sequence is used to select the RSSI display option: 

Label: RSSI DISPLAY
Data: <type>

The type value is set to 

0

for direct readout in dBm or 

1

for bar graph.

If the RSSI display type value is greater than 1, it is considered invalid.
The factory default is 

0

.

Enter LCD Display Contrast

The following key sequence is used to enter the LCD Display Contrast:

Label: LCD CONTRAST
Data: <contrast>

If the LCD contrast is not in the range of 

0

(darkest contrast) to 

19

(lightest contrast), it is considered invalid. The factory default is 

10

.

Enter Zero-Delay Dial

The following key sequence is used to enter the Zero Delay Dial option:

Label: ZERO-DELAY DIAL
Data: <zero-delay dial>

The zero delay dial value is set to 

0

for Disable and 

1

for Enable. The

factory default is 

1

(Enable).

Содержание PHONECELL SX4D GSM

Страница 1: ...Digital call clarity and privacy at your fingertips 03 09 01 Part No 56020401 PHONECELL SX4D GSM DESKTOP PHONE 900 MHZ VOICE MODEL and 1800 MHZ VOICE MODEL USER MANUAL...

Страница 2: ...PHONECELL SX4D GSM DESKTOP PHONE 900 MHZ VOICE MODEL and 1800 MHZ VOICE MODEL USER MANUAL...

Страница 3: ...0 Fax 847 247 0021 E mail mainoffice telular com http www telular com Patents Telular Corporation products are protected and manufactured under one or more of the following U S patents and related int...

Страница 4: ...ell SX4D Operation 18 LCD Display 18 Phonecell SX4D Power Mode 19 Phonecell SX4D Normal Mode 19 Phonecell SX4D Controls 22 How to Place a Call 23 How to Receive a Call 23 How to End a Call 23 Hookflas...

Страница 5: ...th agencies and industry developed this updated Standard In March 1993 the U S Federal Communications Commission FCC proposed the adoption of this updated Standard The design of your Telular Phonecell...

Страница 6: ...posted in the areas instruct you to do so Hospitals or health care facilities may be using equipment that could be sensitive to external RF energy Aircraft Turn OFF your Phonecell SX4D before boarding...

Страница 7: ...o Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio fre...

Страница 8: ...use and service for a period of fifteen 15 months from date of shipment from Telular Telular at its option shall at no charge either repair replace or refund the purchase price of the Product during t...

Страница 9: ...posed parts that are scratched or damaged due to customer normal use i Costs and expenses including without limitation handling labor and transportation incurred in returning Product for warranty serv...

Страница 10: ...Drill Bit 1 Screwdriver 2 11 2 inch 3 75 cm Mounting Screws The Phonecell SX4D GSM 900 and SX4D GSM 1800 come with the following Phonecell SX4D Desktop Phone Antenna 6 VDC Power Supply AC to DC Carefu...

Страница 11: ...pages 13 15 If your Phonecell did not come with a pre installed mini SIM card you need to perform the SIM Card Installation and SIM PIN Setup Otherwise continue to Step 4 Step 4 Determine Phonecell S...

Страница 12: ...ngly Antenna Setup Connect the antenna to the TNC antenna connector on the rear panel of the Phonecell SX4D see Figure 1 Antenna Tips Locate the antenna above ground and as close to windows or exterio...

Страница 13: ...s the battery access door tab and remove the battery access door Install the batteries and reinstall the battery access door see Figure 9 A switch is used to select either AC or internal battery opera...

Страница 14: ...ew see Figure 6 3 Open the SIM compartment holder 4 Line up the mini SIM card with the arrow on the SIM card holder 5 Gently insert the mini SIM card in the slot of the SIM card holder see Figure 6 6...

Страница 15: ...e is completed 1 Lift up the handset take off hook 2 Press 04 old_PIN new PIN new PIN NOTE You must know the old PIN to change it and the new PIN must be 4 to 8 digits 0 9 in length 3 Incorrect entry...

Страница 16: ...ous page for instructions on how to enter the auto entry PIN value Enter Automatic PIN Entry Option The following key sequence is used to enable or disable the automatic PIN entry Label ENABLE AUTO PI...

Страница 17: ...ble but may be hung on a wall if that is more convenient for the user For best results the unit should be mounted near a window or on an exterior wall see Figure 7 and Figure 8 SX4D GSM 900 SX4D GSM 1...

Страница 18: ...e edge of this page as a template These hole locations match the mount ing hooks on the back of the unit see Figure 9 4 Using the two hole locations marked above drill two holes into the wall 5 Instal...

Страница 19: ...f a call Used only in the Normal Mode Battery Indicates that the Phonecell SX4D is operating on the internal batteries Used in all modes Dialed Digits The middle row is used to display dialed digits f...

Страница 20: ...on screen will be displayed Phonecell SX4D Normal Mode The Phonecell SX4D operates in the Normal Mode The functions of the Phonecell SX4D are displayed on the LCD Legends Row Top Row Battery The Batte...

Страница 21: ...the on hook call Alert sounds The incoming call number display is turned off when the call is answered handset is off hook Caller ID will also be shown for off hook call alerts NOTE The incoming call...

Страница 22: ...right is used as a separator only and does not pro vide information see Figure 15 A char acter is displayed and is always illuminated In Use Indicator The In Use Indicator displays a U in the 14th cha...

Страница 23: ...to nominal by resetting the Phonecell power Off On Voicemail Retrieval The Voicemail Retrieval key causes the Phonecell SX4D to dial a programmable DTMF digit string allowing the user to retrieve voi...

Страница 24: ...okflash Function There are two ways to initiate the Hookflash function Press the FLASH key on your Phonecell SX4D Press the hang up or switch hook mechanism on your Phonecell SX4D once quickly approxi...

Страница 25: ...e Equipment Personalization MEP The terminal will support all five lock type features of GSM 02 22 Personalization features check information stored in the terminal which limits the SIMs with which th...

Страница 26: ...orward on no answer waits an amount of time equal to the delay for the phone to be answered before declaring no answer and forwarding the call Teleservice 10 All Teleservices 11 Speech 12 Data 13 Fax...

Страница 27: ...rk send after the stated delay all incoming calls or just those associated with a specific teleservice addressed to the called sub scriber s directory number to another directory number Register 002 P...

Страница 28: ...try of the served subscriber and to sub scribers of the fixed network s in the home PLMN country Activate 332 Password TeleService Send Deactivate 332 Password TeleService Send Barring of All Incoming...

Страница 29: ...tivate 353 Password TeleService Send Unstructured Supplementary Services Allows a user and a PLMN operator defined application to communicate in a way that is transparent to the terminal and to interm...

Страница 30: ...proper connection to AC If AC power is unavailable verify that the batteries are in good condition and that the battery switch is in the battery power active position Battery Backup Failure The Phonec...

Страница 31: ...the user and technician command modes 3 The Up Down keys are used to scroll through the menu items 4 Pressing any numeric key or if allowed the or key when a label is displayed causes The Dialed Digi...

Страница 32: ...factory default is 2 Enter Auto Send Delay The following key sequence is used to enter the auto send delay Label AUTO SEND DELAY Data delay If the delay is not in the range of 2 to 20 seconds it is c...

Страница 33: ...shing the dialed digit row The following commands are displayed when the technician enters the program ming mode In the following sections an entered value is comprised of the dig its 0 through 9 Ente...

Страница 34: ...elect if in call DTMF signaling is enabled Label IN CALL DTMF Data in call DTMF signaling enabled The in call DTMF signaling value is set to 0 for disabled or 1 for enabled If the in call DTMF signali...

Страница 35: ...ge 0 to 3 it is consid ered invalid The MEP password is a special value available only to authorized personnel The factory default is set to 0 deactivated Enter Mobile Equipment Personalization for Se...

Страница 36: ...2001 TELULAR CORPORATION Part No 56020401...

Отзывы: