Quick Manual v1.5 // FMC13A
16
Telematics
ELECTRICAL
CHARACTERISTICS
Characteristic description
Value
Supply voltage
Min.
Typ.
Max.
Unit
Supply Voltage
(Recommended
Operating Conditions)
+10
+30
V
Digital output (open drain grade)
Drain current (Digital
Output OFF)
120
μA
Drain current
(Digital Output ON,
Recommended
Operating Conditions)
0.1
0.5
A
Static Drain-Source
resistance (Digital Output
ON)
400
600
mΩ
Digital input
Input resistance (DIN1)
47
kΩ
Input resistance (DIN2)
38.45
kΩ
Input resistance (DIN3)
150
kΩ
Input voltage
(Recommended
Operating Conditions)
0
Supply
voltage V
Input Voltage threshold
(DIN1)
7.5
V
Input Voltage threshold
(DIN2)
2.5
V
Input Voltage threshold
(DIN3)
2.5
V
Analog input
Input voltage
(Recommended
Operating Conditions),
Range 1
0
V
Input resistance, Range 1
38.45
kΩ
Measurement error on
12V, Range 1
0.9
%
Additional error on 12 V,
Range 1
108
mV
Measurement error on
30 V, Range 1
0.33
%
Additional error on 30 V,
Range 1
88
mV
Input Voltage
(Recommended
Operating Conditions),
Range 2
0