Quick Manual v1.5 // FMC13A
11
Telematics
DEFAULT CONFIGURATION SETTINGS
DEVICE MAKES A RECORD ON MOVING IF ONE OF THESE EVENTS HAPPEN:
MOVEMENT AND IGNITION DETECTION:
VEHICLE MOVEMENT
will be detected by accelerometer
300
seconds passes
VEHICLE DRIVES
100 meters
IGNITION WILL BE DETECTED
by vehicle power voltage
between 13,2 – 30 V
VEHICLE TURNS
10 degrees
SPEED DIFFERENCE
between last coordinate and current
position is greater than 10 km/h
After successful SMS configuration, FMC13A device will synchronize time and update records to configured server. Time intervals
and default I/O elements can be changed by using
.
1
wiki.teltonika-gps.com/view/Teltonika_Configurator
2
wiki.teltonika-gps.com/view/Template:FMB_Device_Family_Parameter_list
DEVICE MAKES A RECORD ON STOP IF:
RECORDS SENDING TO SERVER:
1 HOUR PASSES
while vehicle is stationary and ignition
is off
IF DEVICE HAS MADE A RECORD
it is sent to the server every 120 seconds