62
8.2.5
Static Navigation (ID=1003)
When static navigation is enabled, FMA120 filters out GPS jumps, when it is not moving.
When it is disabled, it does not make any changes to collected GPS data.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
1
1
U8
8.2.6
Ignition source (ID=1004)
Device can operate and change its working mode according to motion detection source:
Power Voltage (value 0), Digital Input 1 (value 1), movement (value 2).
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
2
-
Power Voltage High Level
(ID=1005)
Power Voltage Low Level
(ID=1006)
U8
8.2.7
Power Voltage High Level (ID=1005)
When ignition source is selected as Power Voltage High level for ignition detection must be
set.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
30000
-
Ignition source (ID=1004)
Power Voltage Low Level
(ID=1006)
U16
8.2.8
Power Voltage Low Level (ID=1006)
When ignition source is selected as Power Voltage High level for ignition detection must be
set.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
30000
-
Ignition source (ID=1004)
Power Voltage High Level
(ID=1005)
U16
8.2.9
Saving/Sending without time synchronization (ID=201)
When this feature is enabled (value = 1), then records can be saved and sent to server
without time synchronization.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
1
1
U8
8.2.10
GNSS System (ID=202)
This parameter sets Satellite System, available values: 0
–
GNSS (all available); 1
–
GPS only;
2
–
GLONASS only.
Содержание FMA120