103
9.7
Get CAN info by SMS
Full LV-CAN information via SMS:
SMS Text: “lvcangetinfo”
Response:
“
Prog: 139
SWRevison: 6
KernVer: 10
KernVar: 49
MdlID: 8884443332221110
”
9.8
Clear counted parameters value
It is possible to clear Total Mileage (counted), Engine Work Time (counted), Fuel Consumed (counted)
parameters with following SMS command.
SMS text: ”lvcanclear x”
Possible values of x:
0
–
Engine work time (counted);
1
–
Fuel Consumed (counted);
2
–
Vehicle Mileage (counted);
10
MOUNTING RECOMMENDATIONS
10.1
Connecting Wires
•
Wires should be connected while module is not plugged in.
•
Wires should be fastened to the other wires or non-moving parts. Try to avoid heat
emitting and moving objects near the wires.
•
The connections should not be seen very clearly. If factory isolation was removed while
connecting wires, it should be applied again.
•
If the wires are placed in the exterior or in places where they can be damaged or exposed
to heat, humidity, dirt, etc., additional isolation should be applied.
•
Wires cannot be connected to the board computers or control units.
10.2
Connecting Power Source
•
Be sure that after the car computer falls asleep, power is still available on chosen wire.
Depending on car, this may happen in 5 to 30 minutes period.
•
When module is connected, be sure to measure voltage again if it did not decrease.
•
It is recommended to connect to the main power cable in the fuse box.
10.3
Connecting Ignition Wire
•
Be sure to check if it is a real ignition wire
–
power does not disappear while starting the
engine.
•
Check if this is not an ACC wire (when key is in the first position, most electronics of the
vehicle are available).
•
Check if power is still available when you turn off any of vehicles devices.
Содержание FMA120
Страница 1: ...FMA120 User Manual V1 06 This version is suitable for device with firmware version 01 24 xx ...
Страница 6: ...6 10 4 CONNECTING GROUND WIRE 104 11 CHANGE LOG 106 ...
Страница 36: ...36 Figure 25 Data Acquisition Mode configuration ...