Table 2 Polling Controller Programming Commands
Command
Description
Valid entries
(x = /n=/y=)
Factory
Default
Standalone
Default
Customer
Settings
*00#*00#
Restore to Factory Defaults
—
—
*00#*02#
Restore to Standalone
Defaults
*01#x#
Enable Automatic Transfer
codes
x = 0-16
1-16 are port
numbers
0 = disabled
0
0
*02#x#
No Default Ringing
(Turn Default Ringing on and
off)
0 = disabled
1 = enabled
0
0
*03#x#
End Dial String
(Adds # terminator)
0 = disabled
1 = enabled
0
0
*04#x#
Recognize programmable
routing codes
0 = disabled
1 = enabled
(Also Line Split
Method must be
Six Digits)
0
0
*05#x#
Line Split Method:
(Routing Code Detect or Six
Digits)
0 = routing code
detect
1 = delay after
six digits
0
0
*06#x#
Transfer Code Transmit Delay
1-60 seconds
(Only active if
Line Split Method
is Six Digits)
16
16
*07#x#
Number of Transfer Code
Transmissions
0 = no limit
4-20 = give up
after this number
of transmissions
9
9