Mounting instructions for TQ12 ver 2 Production tracker
- Installation with relay to collect production data and constant positioning
This scenario should be used when the unit shall collect the machine's running and production hours, and alarms. This scenario also
supports constant positioning, which means that the device can send in position after the main switch has been turned off.
This is done by connecting the digital inputs (running hours, production hours and alarms) through relays that break when the main power
switch is turned off. The relay should be NO (normally opened) or alternating 1 pole (12-24VDC).
Suitable relays can be ordered from TelliQ AB.
NOTE! If the unit is installed as described below without relay, running and production hours will be counted when the main switch is off
and provide incorrect data in the TelliQ system and increase the power consumption of the machine's battery.
●
Red
wire connects to b at a suitable location. Use a 2 or 3 A fuse to protect the unit. The power must be constant when
machine is running
●
Black
wire connected to battery - not chassis GND.
●
Yellow
wire is connected to the signal when the engine is switched on (hour counter), such as the ignition by relay as shown in the
picture below. The signal should be 7.5-30 VDC.
●
Optional,
White/Green
wire is connected to the signal that is high when the machine produces. The signal should be 2.5-30 VDC.
●
Optional,
White
wire is connected to the alarm (2.5-30 VDC).
●
The other wires are used for TelliQ accessories.
NOTE! The unit consumes < 6mA when the machine is not in use