Mounting instructions for TQ12 ver 2 Production tracker
- Main power switch on negative side
The following scenario must be used if the machine's main power switch is located on
the negative battery side.
- Installation for collecting positioning and production data
This scenario should be used when the unit shall collect the machine's running and
production hours, and alarms. When the main switch is turned off the unit has limited
possibility to send data. The unit is equipped with a back-up battery, fully charged and in good condition it can send positions for some
hours after the main power switch is turned off. In this scenario, the unit draws no power from the battery when the main power switch is
turned off.
●
Red
wire connects to b at a suitable location. Use a 2 or 3 A fuse to protect the unit. The power must be constant when
machine is running
●
Black
wire is connected to ground.
NOTE!
Shall not
be installed before the machine's main power switch!
●
Yellow
wire is connected to the signal when the engine is turned on, such as the ignition. The signal should be 7.5-30 VDC.
●
Optional,
White/Green
wire is connected to the signal that is high when the machine produces. The signal should be 2.5-30 VDC.
●
Optional,
White
wire is connected to the alarm (2.5-30 VDC).
●
The other wires are used for TelliQ accessories.
Page
3 (8)