19
•
Maximal Alarming time
: can be set between 5 and 25 minutes, means how long
should the module make attempts of transmission through GPRS or GSM after an
event occurred. When this time expires and not all of the calls and SMS transmissions
etc. succeed, the module will cancel the alarm process and will not make any more
attempts of notification concerning the specific event. This only refers to that specific
event, calls and SMS messages occurred by other new events will continue the
notification.
•
Maximal number of alarms from one zone
: it can be set between 0 and 25 how
many notifications to be sent maximum from one zone. Herewith is avoidable that a
faulty zone occurs continuously alarms. Disarming and rearming the system enables
the zone again, therefore it can send alarms but once more only the maximum
number of alarms set. In case of setting value
0
, the number of alarm notifications
transmittable is unconstricted. If „Always armed” mode is set as arming/disarming
method then this function cannot be used according to the meaning.
•
Test report frequency
: the frequency of test report messages can be set in hours
(0-255), that is in how many hours interval shall the module send a test report. Setting
value
0
means the module does not send test reports.
•
Test report time
: here the time of the test report can be set in hh:mm format or on
the left of the field the hours and on the right the minutes can be set by shifting. The
module takes this time into account on the first day of every month, that is at this time
of the first day of every month it sends a test report then within the hour set at
frequency, and so on. On the first day of next month it will send a test report again at
the given time..
•
Send test report now
: by clicking on this button a test report can be sent at any time.
•
Arming is not allowed if any zone is active
: if set, arming is prohibited if any of the
zones is active.
When you have finished programming save the changes by pressing "
Store changes
"
button or press "
Cancel
" to close the window without saving.
6.8 Change module's password
If you wish to change the password of the module press "
Change module's password
".
After entering the old password, the new password can be set, which has to be
re-entered for verification.
If you have forgotten the old password, then it cannot be changed, in this case turn to
the manufacturer using e-mail address found on
www.tell.hu
site and supply the
following information:
•
Phone number of the SIM card placed in the module