INSTALLATION AND APPLICATION MANUAL 

 

 

for module version V1.20.1837 and up 

 

Document version: 1.61  12.08.2013 

Содержание DUALCOM SIA IP

Страница 1: ...DUALCOMSIA IP INSTALLATION AND APPLICATION MANUAL for module version V1 20 1837 and up Document version 1 61 12 08 2013...

Страница 2: ...he programming software 6 5 1 3 Phone numbers 6 5 1 4 SIM A SIM B GPRS settings 7 5 1 5 Input settings 8 5 1 6 Relay outputs 10 5 2 Configuring by SMS commands 11 5 3 Module status monitoring 13 5 3 1...

Страница 3: ...IA DC 09 2007 standard No need for a central server only an IP receiver with internet connection is necessary The module works with the following receiver types TELLMon AMR 08 and ENIGMA II 2 Function...

Страница 4: ...ferent networks and to the different remote monitoring stations in parallel Due to the parallel operation ideally each receiver receives the event roughly at the same time this is an average of 5 seco...

Страница 5: ...ram window Programming Copy the programming software from the module to a suitable place on the PC The software is available in the following folder Drive letter Software Remoter Remoter exe Start the...

Страница 6: ...nction buttons of the programming software Read read settings from the connected module Write write settings to the connected module Open load settings from file Save save settings to file 5 1 3 Phone...

Страница 7: ...gure the IP addresses in pairs which means if IP A is set B must also be set and vice versa Primary 1A 2A the primary receivers belonging to SIM A network Primary 1B 2B the primary receivers belonging...

Страница 8: ...ow battery voltage threshold the module is able to monitor the supply voltage This function is useful when the module is powered from uninterrupted power supply provided with a backup battery recommen...

Страница 9: ...The restoration event is sent automatically upon restore for inputs according to the input sensitivity settings For inputs and tamper event the module sends the zone number 001 006 automatically accor...

Страница 10: ...f the 6 inputs is activated and remains activated as long as any input is active Indicates battery trouble the output is activated upon battery trouble and remains activated as long as the battery tro...

Страница 11: ...Command Value Superuser registration SUPERUSER registers the sender s phone number Modifying deleting the Superuser SU phone number APN assigned to SIM A APNA APN name e g internet APN user name assi...

Страница 12: ...hreshold BATH e g 12500 9000 30000 mV Restart module after 30sec RESET 1 The module sends response message about the modifications e g IP1A OK except for the superuser registration Examples Registerin...

Страница 13: ...ersion the module s hardware version Firmware version the module s firmware version System timer Date time the date and time setting of the module s internal clock Uptime the time elapsed from last mo...

Страница 14: ...ection ok ready Online ACK error IP connection ok but no acknowledgement signal is received alarm monitoring software serial connection error Offline No response no response is received from the confi...

Страница 15: ...wet places or places with high degree of humidity Connecting the GSM antenna the GSM antennas can be fixed in the FME M connectors found on the panel The antennas supplied with the module provide good...

Страница 16: ...security lock downwards towards USB connector until it clicks Check the SIM cards to be inserted properly Check the antennas to be fixed properly in the FME M connectors The device can be powered up...