Furthermore, if the device is developed for the US and/or Canada market, it must comply with the
FCC and/or IC approval requirements.
NOTE:
This device is to be used only for mobile and fixed application. The antenna(s) used for this
transmitter must be installed to provide a separation distance of at least 20 cm from all persons
and must not be co-located or operating in conjunction with any other antenna or transmitter.
End-Users must be provided with transmitter operation conditions for satisfying RF exposure
compliance. OEM integrators must ensure that the end user has no manual instructions to remove
or install the LE910C1 module. Antennas used for this OEM module must not exceed 3dBi gain for
mobile and fixed operating configurations.
7.2.
GSM/WCDMA/LTE Antenna – PCB Line Guidelines
•
Make sure that the transmission line’s characteristic impedance is 50 Ohm.
•
Keep the line on the PCB as short as possible since the antenna line loss should be less than
around 0.3 dB.
•
Line geometry should have uniform characteristics, constant cross sections, and avoid
meanders and abrupt curves.
•
Any suitable geometry/structure can be used for implementing the printed transmission
line affecting the antenna.
•
If a ground plane is required in the line geometry, this plane must be continuous and
sufficiently extended so the geometry can be as similar as possible to the related canonical
model.
•
Keep, if possible, at least one layer of the PCB used only for the ground plane. If possible,
use this layer as reference ground plane for the transmission line.
•
Surround the PCB transmission line with ground (on both sides). Avoid having other signal
tracks facing the antenna line track directly.
•
Avoid crossing any un-shielded transmission line footprint with other tracks on different
layers.
•
The ground surrounding the antenna line on the PCB must be strictly connected to the main
Ground plane by means of via-holes (once per 2 mm at least) placed close to the ground
edges facing the line track.
•
Place EM-noisy devices as far as possible from LE910C1 antenna line.
•
Keep the antenna line far away from the LE910C1 power supply lines.
•
If EM-noisy devices are present on the PCB hosting the LE910C1, such as fast switching ICs,
take care to shield them with a metal frame cover.