3.1.2.1.
Incoming Terminal I/O Connection
For a Terminal I/O connection it is necessary that the Terminal I/O service and the advertising
mode are enabled. This is the default behavior of the S42/Central.
The S42/Central signals an incoming Terminal I/O connection with the following
event:
RING
CONNECT TIO 0x01
The S42/Central report the incoming Terminal I/O connection with the result
message “RING”. The established Terminal I/O connection is reported with the message
„CONNECT“ including the connection type „TIO“ and a connection handle “0x01”.
The given connection handle is required for detailed activities onto this Terminal I/O
connection.
After reporting the “CONNECT” result message the S42/Central changed from the
AT based “command mode” to the “online data mode”.
3.1.2.2.
Exchange Terminal I/O Data
All data send on the serial interface is transparently sent to the Terminal I/O client side.
All data send by the remote Terminal I/O client is binary output on the serial interface of the
S42/Central.
When a peripheral Terminal I/O server connection is active, it is not possible to create a GATT
connection to a peripheral device.