INSTALL CONFIDEA G3
Within Plixus it is possible to connect the engine to a Confidea G3 wireless system. When connected, Plixus
will treat the units the same way as all other wired units.
Connect Wireless Conference Access Point (WCAP) To
Plixus Network
Use the conference ports on the WCAP to connect to the Plixus engine or a network extender. In some
cases you want to have multiple WCAPs available ( see "Combine Plixus with Confidea G3" on page 67 for
more information). You can daisy chain multiple WCAPs in one branch. We suggest not to put more than
eight WCAPs on one branch.
24V
AUX.
BALANCED
PORT 1
PORT 2
0.625A
Figure 1-47
Back view with conference ports on Confidea G3 WCAP
To supply power to the WCAP you can use its external power supply, but you can also use the power
supplied by the engine or network extender with power over Ethernet.
When your setup contains multiple WCAPs, then these should use a different frequency to allow
successful initialization.
INSTAL L CO NF IDEA G 3
9 2
Содержание Plixus AE-R
Страница 1: ...conference PLIXUS INSTALLATION GUIDE...
Страница 85: ...Figure 1 46 How to attach the uniCOS T MM10 to a fixed surface ATTACH UNICOS T MM10 TO A FIXED SURFACE 85...
Страница 88: ...10 Remove UniCOS F MM 7 From The Bracket 2 mm INSTALL THE UNICOS UNITS IN THE RESPECTIVE MOUNTING BRACKET 88...
Страница 90: ...6 7 POWER 2x RJ 8 9 click click 10 INSTALL THE UNICOS UNITS IN THE RESPECTIVE MOUNTING BRACKET 90...
Страница 91: ...Remove UniCOS F MM 10 From The Bracket 2 mm INSTALL THE UNICOS UNITS IN THE RESPECTIVE MOUNTING BRACKET 91...
Страница 99: ...Figure 1 57 How to detach the nameplate from the mounting bracket and bottom plate MOUNT THE NAMEPLATE 99...
Страница 162: ...TELEVIC CONFERENCE Leo Bekaertlaan 1 8870 Izegem Belgium 32 51 30 30 45 GET IN TOUCH...