Maximum power consumption
71.98.2051 - 71.98.2050
Plixus Nameplate (double sided &
single sided)
4 W
Maximum distance between units
100 m (signal regenerated in every
unit)
Minimum required voltage per unit
36 V
The general rule states that you should use a maximum
20 delegate units per branch / loop
.
Plixus AE-R Power Supply
The Plixus AE-R does not have an internal power supply, however it does have two power connectors. By
default you get one power supply together with the engine. You can extend this power supply with another
as redundancy or when the system requires more power.
To check how many power supplies you require, consult the flowchart shown below.
Plixus NEXT needed?
More than 40 units?
More than 200 W?
Plixus AE-R (71.98.2902)
Plixus Power Supply (71.98.2930)
required for network extender
Plixus AE-R Power Supply (71.98.2931)
for power redundancy
Plixus AE-R (71.98.2902)
2 × Plixus AE-R Power Supply (71.98.2931)
to power units
2 × DIN Rail Power Supply 48 Vdc - 10 A
for power redundancy
Plixus AE-R (71.98.2902)
Plixus AE-R Power Supply (71.98.2931)
for power redundancy
No
Yes
Yes
Yes
No
No
Figure 1-31
How to decide to need an additional Plixus AE-R power supply
PO WER SUPPL Y DESIG N
6 2
Содержание Plixus AE-R
Страница 1: ...conference PLIXUS INSTALLATION GUIDE...
Страница 85: ...Figure 1 46 How to attach the uniCOS T MM10 to a fixed surface ATTACH UNICOS T MM10 TO A FIXED SURFACE 85...
Страница 88: ...10 Remove UniCOS F MM 7 From The Bracket 2 mm INSTALL THE UNICOS UNITS IN THE RESPECTIVE MOUNTING BRACKET 88...
Страница 90: ...6 7 POWER 2x RJ 8 9 click click 10 INSTALL THE UNICOS UNITS IN THE RESPECTIVE MOUNTING BRACKET 90...
Страница 91: ...Remove UniCOS F MM 10 From The Bracket 2 mm INSTALL THE UNICOS UNITS IN THE RESPECTIVE MOUNTING BRACKET 91...
Страница 99: ...Figure 1 57 How to detach the nameplate from the mounting bracket and bottom plate MOUNT THE NAMEPLATE 99...
Страница 162: ...TELEVIC CONFERENCE Leo Bekaertlaan 1 8870 Izegem Belgium 32 51 30 30 45 GET IN TOUCH...