Televes OSSGT Скачать руководство пользователя страница 5

5

EN

1. General Information

This professional fusion splicer includes 6 alignment 
engines to work on the diff erent axes (X, Y, Z), and thus 
automatically achieve an electric arc fusion in as little 
as 8 seconds. Manufactured in high-resistance ABS, its 
transport case not only provides for the equipment 
transport, but also for the operator’s work desk .
Light and compact, it includes all the required accessories.
Its dimensions, weight and 360º protective dome (high- 
density bumper), make this fusion splicer the appropriate 
equipment for any type of installations.
Designed for use in hostile environments, it withstands 
high-speed winds and other adverse environmental 
conditions, is water-resistant, and ensures an unparalleled 
quality throughout the splicing process.
Its user interface is simple and intuitive.
Capable of measuring the cutting angle (identifying 
potential bad adjustments of the cutter) and detecting 
fi ber errors (usually dirt), it allows the detection of 
problems before the fusion takes place.
Thanks to a traction process for the verifi cation of the 
spliced fi ber and to the calculation of optical loss, it helps 
the operator ensure the fusion was performed correctly.
Thanks to its battery (interchangeable from the outside), 
it allows working in places lacking VAC power supply . This 
is complemented with a feature that allows working with 
the fusion splicer while the battery is charging.

Types of fi ber the fusion splicer can work with:

  SM (Single-mode): Single mode (G .652 / G .657) 

  MM (Multi-mode): Multimode (G .651)

  DS (Dispersion): (G .653)

  NZDS (non- zero dispersion): (G .655)

  BIF/UBIF SM

  Standard working diameter: 80 to 150

m.

   External coating diameter: desde 100 to 1000

m. 

   Fiber cleaved length: 5 to 20 mm (standard :16mm).

Accessories included with the fusion splicer

  Carrying case.

    Handle for the fusion splicer and carrying strap for the 

case.

  CD with user manual and software for data download.

   Optical  fi ber cleaver with removable pick-up feature,  

and blade for up to 16 .000 cuts.

  Precision stripper, pre-calibrated for 125, 250 and 900μm

   Power cord, power supply and car adapter (the latter in 

cludes USB output to feed other devices).

   User-removable lithium battery with charge level visual 

indicator.

  Isopropyl alcohol tank with dispenser.

  Plastic tweezers.

  Mount for fi ber protection cooling. 

  Solid plastic screen protector. 

Содержание OSSGT

Страница 1: ...Electric arc fusion splicer Ref 232105 OSSGT Operating instructions w w w t e l e v e s c o m EN Ref 23...

Страница 2: ......

Страница 3: ...ection 10 4 5 6 USB Mode 10 4 6 System Setting 10 4 6 1 ECO Mode 11 5 Splice process 11 5 1 Electrode and element inspection 11 5 2 Fiber preparation 11 5 3 Fiber type 12 5 4 Fiber introduction into t...

Страница 4: ...by falling o crashing You must switch off the equipment and immediately remove the battery Then contact the Technical Support department of Telev s to proceed with its inspection or repair 3 Internal...

Страница 5: ...the spliced fiber and to the calculation of optical loss it helps the operator ensure the fusion was performed correctly Thanks to its battery interchangeable from the outside it allows working in pl...

Страница 6: ...r Front view Side views Fiber clamps Camara lens x2 Electrode x2 V Groove x2 Keyboard 2 Heater Keyboard 1 LCD screen Lashing eyelet Lashing eyelet Battery indicator push button Power supply connector...

Страница 7: ...nace Menu for use based maintenance Sistema System configuration language screen power 4 1 Function Setting In this option the parameters shown below will be configurable Parameter Description Quick A...

Страница 8: ...ows the modification of the enhanced duration of the arc usual value 1000ms It can be increased in case that after splicing there is narrowing detected on the fiber at the splicing spot If the fiber i...

Страница 9: ...displayed Delete records Erases all the records that the device has registered Query fault records Displays the records of all the failed splices Delete fault records Erases all the records of the fa...

Страница 10: ...be displayed on the screen The PC will show a new disc unit containing the folders below For downloading the records you must access the folder RECORD within the same SPLICE TXT is the file that cont...

Страница 11: ...rrors Check the correct alignment of the electrodes and make sure their ends are in good shape Should you find any impurities take them away with a wipe swab dampened with isopropyl alcohol 5 2 Fiber...

Страница 12: ...usly entered the Start menu with the Menu key The fusion splicer will not work unless you are on that menu Check the fibers hanging from the fusion splicer are not blocked by the cover or held by the...

Страница 13: ...g a 45o angle with each other Note Apply a controlled force for the cleaning of the V groove It is a sensitive precision element 6 2 Cameras or lenses Clean the lenses regularly Presence of dirt on th...

Страница 14: ...ting blade and by the means of a screwdriver pull out the screw 3 Replace the cutting blade and re assemble following the steps descrived above in reverse order 6 6 Stripper You should occasionally lu...

Страница 15: ...Y axis 180x magnification X axis or Y axis separately 360 magnification Screen 4 3 high performance LCD Tensile test 2N standar Heat shrink protectors 60 50 45 40 30 and 25mm Electrode duration 3 000...

Страница 16: ...www televes com...

Отзывы: