6.1.3 Troubleshooting
The table below, according to the LEDs status, identifies a possible cause and describes the procedure to fix the problem.
LED
State
Probable Cause
Solution
POWER (A2)
OFF
ONT 769503-SFU not
powered
Verify that the DC power jack is correctly con-
nected to the ONT 769503-SFU and the power
adapter at the wall power socket.
ETHERNET (Left) (A6)
OFF
ETHERNET cable not
connected correctly
Verify that the ETHERNET cable is correctly con-
nected to the ONT 769503-SFU’s ETHERNET Port
and to the WAN Port at the Home Gateway (and
not to a LAN Port for e.g.). Use another Ethernet
cable
GPON LINK (A3)
OFF
Anomaly in the optical
fiber signal
Verify that the optical cable is correctly connected
to the ONT 769503-SFU’s internal optical port and
to the optical wall socket. Verify that the fiber is
intact, it is clean, without cuts, scratches or bends.
AUTH (A4)
OFF
GPON LINK (A3)
ON
ONT 769503-SFU deac-
tivated by the network
administrator
Contact the technical support.
AUTH (A4)
OFF
CATV (A5)
OFF
CATV deactive at the
ONT 769503-SFU
Contact the technical support.
GPON LINK (A3)
Blinking
Authentication Error at
the ONT 769503-SFU
Contact the technical support.
AUTH (A4)
OFF or
Blinking
Table 6-4: ONT 769503-SFU troubleshooting