Teletechnika Ltd. DHE-1000 Скачать руководство пользователя страница 3

 

 

 

Mechanical parameters, operation 

 

The height of the encoder is 1 unit (1U) with 19’’ width and is supplied with standard 

power cable. 

In case of rack-mounted usage, the operator should take care of the proper airflow and 

ventilation! Do not cover the case because it could cause overheating! 

Hardware structure 

Front Panel: 

 

 

State indicator LEDs   LCD 

 

State indicator LEDs: 

Power OK 

            

TS proper 

Encoder setting, boot procedure 

Serious internal problem 

 

LCD: 

2 line 40 character alphanumerical display, representing the state of the equipment on 12 pages: 

 

1

st

 page: 

TS MAC Address: 

The MAC address of the UDP/IP marked ETH port. 

TS IP:Port: 

 

The IP address of the UDP/IP marked port separated by a colon is the port. 

 

2

nd

 page: 

Target IP:Port: 

The IP address of the destination side (DECODER) and the port on which 
the decoder detects and filters. 

Gateway IP: 

 

The IP Address of gateway if we use ‘Through gateway’ TS sending 

(See below!) 

 

 

Содержание DHE-1000

Страница 1: ...DHE 1000 MPEG4 HD ENCODER MPEG4 system with IP output Technical documentation Instruction set Teletechnika Ltd 3rd Edition 6th November 2012...

Страница 2: ...S The output transport stream includes the most important PSI SI tables PAT PMT SDT NIT thus in simpler systems the encoder can be applied even without using a remultiplexer This edition contains a 10...

Страница 3: ...icator LEDs Power OK TS proper Encoder setting boot procedure Serious internal problem LCD 2 line 40 character alphanumerical display representing the state of the equipment on 12 pages 1st page TS MA...

Страница 4: ...the audio coding in kbps possible values are 32 48 56 64 80 96 112 128 160 192 224 256 320 384 Audio Status Indicates that there are embedded audio Present or not Muted 6th page The set PID values PMT...

Страница 5: ...he IP address of the configuration port MASK The network mask of the configuration port 11th page MGMT Gateway The Gateway IP address of the configuration port MGMT MAC address The factory constant MA...

Страница 6: ...lds Its great advantage is that one single coaxial cable can be used for transmitting the picture and sound The standard BNC connector on the back panel of the MPEG 4 encoder is used for connecting th...

Страница 7: ...appear after the points If we have some problem a REBOOT word and the equipment reboots until the successfully boot occurs Then the previously described information displayed on the display Settings T...

Страница 8: ...he page 1 Header Teletechnika official webpage can be reached by clicking the Teletechnika logo at the left corner In the line beginning with NIC is the detailed version number of the used firmware Af...

Страница 9: ...IP settings from the used DHCP server Use the following IP configuration Manual IP network settings IP Address IP address of the equipment s MGMT port Subnet Mask subnet mask of the equipment s MGMT p...

Страница 10: ...pare for sending the network settings if it is done it is marked with DONE line The option to apply settings in the Settings menu you must click Apply Server Settings Telnet Web manager Password Set t...

Страница 11: ...in seconds Monitor Mode Bootup Internal service mode enable disable CPU Performance Mode The internal CPU Performance mode you should be high HTTP Server Port The embedded web server port Default 80...

Страница 12: ...uzzle again a Disconnected label is displayed If you have a physical relationship exists and still get Disconnected appears make sure that only one browser is opened and the device is not busy on the...

Страница 13: ...s parameters are displayed The interface works data query page when you open always happens and it can be set to double click on the desired field and press Enter and rewrite the content fix it you ca...

Страница 14: ...the UDP IP marked port Own MAC The MAC address of the UDP IP marked ETH port Own TS Port The source TS Port Gateway IP The IP Address of gateway if we use Through gateway TS sending Target IP The IP a...

Страница 15: ...ending to Multicast destination Audio bitrate The rate of the audio coding in kbps possible values are 32 48 56 64 80 96 112 128 160 192 224 256 320 384 PSI Table Generator Enabled Disabled The enabli...

Отзывы: