TMP4100-Series Installation/Maintenance
1-12
33480D01.DOC
Change 1
TMP4150, TMP4155 Mounting Instructions
Perform the following procedures to mount the TMP4150 and TMP4155 marking heads onto a standard
Telesis tool stand or onto a customer-supplied fixture, as applicable.
Telesis Tool Stand P/N 27200
Note: Mounting hardware for the marking head is supplied in the standard tool stand kit (26208).
1.
To allow the marker cable to reach the controller, ensure the marking head location is within 4m
(13 ft.) of the proposed controller location.
2.
Locate the two threaded holes in the mounting plate attached to the marker.
Refer to Figure 1-3 for mounting hole dimensions and locations.
3.
Align these holes with the lowest two holes on the tool stand carriage.
4.
Using two ½-13 x 1.25-in. hex head bolts (15294) and two ½-in. AN960-816 flat washers (11445),
mount the marker to the tool stand carriage. (Bolts insert from behind the carriage.) Tighten securely.
5.
Connect the drive air (black) tubing to the drive air fitting on the marking head (marked “D”).
6.
Connect the return air (natural) tubing to the return air fitting on the marking head (marked “R”).
7. Proceed
with
Filter/Regulator Unit Installation.
Customer-Supplied Fixture
Note: Mounting hardware for customer-supplied fixtures is not provided.
1.
To allow the marker cable to reach the controller, ensure the marking head location is within 4m
(13 ft.) of the proposed controller location.
2.
Locate the four through holes near the corners of the mounting plate attached to the marker.
Refer to Figure 1-3 for mounting hole dimensions and locations.
3.
Using four ¼-in. (or 6 mm) bolts, four flat washers, four lock washers, and four hex nuts, attach the
marker to the fixture. Tighten securely.
4.
Connect the drive air (black) tubing to the drive air fitting on the marking head (marked “D”).
5.
Connect the return air (natural) tubing to the return air fitting on the marking head (marked “R”).
6. Proceed
with
Filter/Regulator Unit Installation.
Содержание PINSTAMP TMP4100 Series
Страница 2: ......
Страница 4: ...TMP4100 Series Installation Maintenance ii 33480D01 DOC Change 1 This page intentionally left blank...
Страница 10: ...TMP4100 Series Installation Maintenance viii 33480D01 DOC This page intentionally left blank...
Страница 23: ...TMP4100 Series Installation Maintenance 33480D01 DOC 1 13...
Страница 24: ...TMP4100 Series Installation Maintenance 1 14 33480D01 DOC This page intentionally left blank...
Страница 25: ...TMP4100 Series Installation Maintenance 33480D01 DOC 1 15...
Страница 28: ...TMP4100 Series Installation Maintenance 1 18 33480D01 DOC This page intentionally left blank...
Страница 52: ...TMP4100 Series Installation Maintenance 2 24 33480D01 DOC This page intentionally left blank...
Страница 54: ...Appendix A A 2 33480D01 DOC This page intentionally left blank...