background image

    

Table of Contents

Next Page

TELES iGATE FCT

User’s Manual

              

    

Содержание iGATE FCT

Страница 1: ...Table of Contents Next Page TELES iGATE FCT User s Manual...

Страница 2: ...Version Information and Disclaimer iGATE FCT carries CE Certification This manual is applicable to TELES iGATE FCT with soft ware versions 0218 or higher These apply to units with part number Q11 1110...

Страница 3: ...mmary 12 Features 13 Audio Gain 13 Call Duration Limit 13 Calling Line Identification Restriction CLIR 14 Clearing a Lock 14 Erase SMS Inbox of the SIM card 14 Immediate Dialing 15 Interdigit Timeout...

Страница 4: ...T User s Guide 1 Previous Page Table of Contents Next Page Chapter 1 Introduction This section includes Overview on page 2 Product Components ID on page 2 Contents of Package on page 3 Safety Precauti...

Страница 5: ...is transparent The PABX recognizes iGATE FCT as a trunk interface and the routing is done in the PABX itself In a PABX that does not support LCR the user must select the proper trunk for the call The...

Страница 6: ...ety Precautions To avoid injury and prevent equipment damage observe the following safety precautions Do not ship equipment unless it is properly packed in its original wrapping and shipping container...

Страница 7: ...e 4 Previous Page Table of Contents Next Page Chapter 2 Getting Started This section includes Installing the Unit on page 5 Initial Start up and LEDs on page 7 Testing the Installation on page 8 Instr...

Страница 8: ...ferred 6 Select a location for the antenna The location must meet the following criteria at least one meter away from the unit with room for the metal plate with room for the antenna to stand in an up...

Страница 9: ...Line Connector Pin Layout Warning Do not use the reserved pins Note The line can use either pins 3 and 4 or pins 2 and 5 12 Ensure that the PABX is properly configured For details regarding the progr...

Страница 10: ...t up and LEDs Initial Start up and LEDs After the power cable is attached the POWER LED should be illuminated If it is not ensure that the cable is properly connected to the unit and to the AC mains D...

Страница 11: ...LED is red Note Ensure that the dialed number does not conflict with the toll restriction rules if activated Checking Incoming Calls 1 Using a second phone dial the phone number of the SIM card insert...

Страница 12: ...ial If Toll Restriction is active in a PABX without LCR some destinations will not be reachable because the call will be too expensive Use the proper prefix If Call Duration Limit is active calls long...

Страница 13: ...T User s Guide 10 Previous Page Table of Contents Next Page Chapter 3 Programming This section includes How to Program on page 11 Programming Summary on page 12 Features on page 13 Factory Default Val...

Страница 14: ...tion confirmation tone 2 short beeps indicate rejection or inability to perform the command rejection tone 3 Enter parameters using the DTMF tones We recom mended that you check the function of every...

Страница 15: ...g on page 16 6110 Change SIM PIN code See PIN Code Programming on page 16 6122 Clear Channel Lock See Clearing a Lock on page 14 6133 Call Duration Limit See Call Duration Limit on page 13 6150 Erase...

Страница 16: ...igits The unit emits the confirmation tone Wait until the call is answered 4 Dial either 70 for Tx gain 71 for Rx gain The unit emits the confirmation tone 5 Adjust the volume by pressing the keys on...

Страница 17: ...arty The unit emits the confirmation tone Clearing a Lock Lock occurs after an unsuccessful attempt to change the PIN code The unit will not perform any command rele vant to a PIN code change until th...

Страница 18: ...r example 9 shorter numbers are sent to the cellular network after the preset delay or after pressing the sign 1 Dial 1343 The unit enters the programming mode and emits the confirmation tone 2 Dial 3...

Страница 19: ...is wrong the unit locks itself ceases functioning and the STATUS LED blinks See Clearing a Lock on page 14 Note The unit locks in order to prevent the SIM card from locking SIM cards lock after 3 fai...

Страница 20: ...urrent PIN code of the unit 1 Reset the unit to the factory default setting See Restore Factory Default on page 18 2 Set the SIM card s PIN to 1234 To program a SIM card place it in a mobile phone and...

Страница 21: ...and recon nect it Set Pulse Drop Signaling Method If the PABX trunk connected to the unit supports Pulse Drop use this command to set the unit to Pulse Drop sig nalling mode 1 Dial 1343 The unit ente...

Страница 22: ...g those starting with the sign are never blocked This ensures that emergency and special service calls are placed The list of allowed prefixes can include up to 10 entries The minimum length of a pref...

Страница 23: ...ds Table 5 Toll Restriction Commands Command Result 9193 Disables the Toll Restriction fea ture This does not erase the entries in the table 9195 fol lowed by a prefix followed by the sign This delete...

Страница 24: ...TELES iGATE FCT User s Guide 21 Previous Page Table of Contents Next Page Chapter 4 SMS This section includes SMS Commands Overview on page 22 GET Command Table on page 22 SET Command Table on page 23...

Страница 25: ...ng programming feature Note The speed SMS messages are delivered is dependent upon the network There may be a delay GET Command Table Table 6 GET Command Table Command Syntax Command Feature Applicabl...

Страница 26: ...ommand Feature Applicable Response Table 7 SET Command Table Command Syntax Command Feature Applicable Response SIG P Set Signalling method to Pulse Drop Line Signal is Pulse Drop XX Where XX is the w...

Страница 27: ...User s Guide 24 Previous Page Table of Contents Next Page Chapter 5 Miscellaneous This section includes Call Progress Tones on page 25 LED Indications on page 25 Troubleshooting on page 26 Specificat...

Страница 28: ...the LED turns off a few seconds every 15 sec onds of operation During a call the indication is fro zen at that which existed when the call started STATUS Indicates the channel oper ational status On T...

Страница 29: ...Try using another phone 6 Dial tone does not stop Dial tone continues after dialling first digit Use a different phone Reset the unit reconnect the power supply 7 Can not connect to a destina tion Th...

Страница 30: ...pin 2 3 TIP pin 4 5 RING Data Port Specifications Interface port RS232 Protocol AT Command Compatible GSM Channel Specifications Dual band GSM 900 1800Mhz or 850 1900MHz Standards Type Approval CE mar...