Setup Pocket - Pattern 8
Figure 5-9, Setting Pocket Limits
Next set the limits of the pocket with the 8 limit points. The limit points can be selected
by pressing the blue arrow button to cycle around the 8 directions. Each time you press
the blue direction arrow the sweep will switch to the next setup point. Two green lines
are drawn to show the available area. First adjust the distance from center with the
radius value. If you need to make a rotational adjustment use the angle adjustment to
move +/-22 degrees. When you are satisfied with all five points then push the
Ok
button
(Press Cancel to not save changes to pocket setup).
Once the center and limits have been set it is a good idea to make a note of the
settings. The
Reset
button will reset all values of the current pocket setup to their
minimums. There is a confirmation screen to prevent accidental resetting. The black box
is the usable area that defines the maximum output of 1.6 or 3.0 amps (depending on
model).
5.4 Copy Pocket Setup
Figure 5-10, Copy Pocket Setup
The pocket setup can be copied to other patterns. Normally copying to ALL patterns
would be desirable if all the pockets in the e-beam source are the same size.