R305 AT Commands
©2011 Telegesis (UK) Ltd
- 99 -
AT Command Manual (Rev 3.05)
9 Upgrading from R2xx to R305 on the ETRX2 Series
R305 firmware can be loaded on to an ETRX2 by bootloading through the serial port or by re-
flashing with an Ember Insight Adaptor. Cloning over the air is tricky because the new R305 node
and the old R2xx node will not join the same PAN. It is possible to clone by using an extra R2xx
device, as shown in the step-by-step guide below.
Figure 2. Cloning from an R305 device
R305
S00=0004
R305
channel 13
R305
S00=0004
R2xx
R2xx
Start with 3 modules.
Set the channel
mask on the R305
source
R2xx
R2xx
ZC
ZR
AT+EN
Establish a PAN on
any channel
R2xx
R2xx
AT+CLONE
Start to clone from a
dummy device
Unplug the target
before the cloning is
complete
R305
S00=0004
R???
AT+EN
Bootload R305 on to
the source device, or
replace it with the
R305 device.
Establish a PAN.
Plug in the target
device
R305
S00=0004
R???
AT+RECOVER
channel 13
Start the recovery
process
R2xx