R305 AT Commands
©2011 Telegesis (UK) Ltd
- 13 -
AT Command Manual (Rev 3.05)
+CLONE
– Clone Local Node To Remote Node (ETRX2 Series only)
Execute Command
AT+CLONE:<EUI64>,<password>
Use on:
Source: FFD, COO
Destination: All device types
Notes
The default password for R3xx nodes is
“password”.
A description of the cloning process can be
found in the Development Kit Product
Manual.
Response
Cloning…
Remote Response
ENTERING BLOAD
or
ERROR<errorcode>
Where <errorcode> represents the error code
explained in section 3.
This command clones the firmware of the local
node to a remote node within the same PAN,
whose address is given by <EUI64>.
<password>
represents
the
remote
node
‟s
8-character password. After completion a soft
reset is caused on the remote end.
SW release
R304
+PASSTHROUGH
– Pass new Firmware Image To Remote Node (ETRX3 Series Only)
Execute Command
AT+PASSTHROUGH:<EUI64>,<password>
Use on:
Source: FFD, COO
Destination: All device types
Notes
The default password for R3xx nodes is
“password”.
A description of the passthrough process can
be found in the Development Kit Product
Manual; it is the same procedure as cloning.
Response
PASSTHROUGH BLOAD...
Please start .ebl upload image...
Remote Response
ENTERING BLOAD
or
ERROR<errorcode>
Where <errorcode> represents the error code
explained in section 3.
<password> represents the remote node‟s
8-character password. After completion a soft
reset is caused on the remote end.
SW release
R304