![Telegan Tempest 50 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/telegan/tempest-50/tempest-50_user-manual_1081820019.webp)
1 Print
(Optional)
Pressing the print function key will print the emissions data in the
following format (see below).
All temperature (Key 7 - Temperature) emissions (Key 8 -
Emissions) and efficiency (Key 9 - Efficiency) data will be printed.
If the probe is not attached correctly (Section 5.2) or the stack and
intake thermocouples are not connected then the temperature data
will not
be printed.
If the optional pressure or nitric oxide (NO) sensors are not fitted
then the respective data will be absent from the print-out and
display.
- - - - - - - - - - - - - - - -
* * *
T E L E G A N
* * *
* *
T E M P E S T
5 0
* *
D A T E
0 9 - 1 9 - 0 2
T I M E
1 5 : 1 1 : 0 6
N A T U R A L
G A S
A M B I E N T
C
2 3
S T A C K
C
1 8 7
N E T T
C
1 6 2
I N T A K E
C
2 5
O 2
%
.
.
.
.
1 6 .
3
C O
p p m .
.
.
.
.
3 5
C O 2
%
.
.
.
.
.
3 .
5
X A I R
%
9 5
R A T I O
E F F
%
( N )
8 5 .
5
P r s .
m B a r
9 7 5
N O
p p m
.
.
.
.
.
1 5
N O x
p p m
.
.
.
.
.
1 8
- - - - - - - - - - - - - - - -