V1.1
25
8
Vertical range is not
within 90
2 degree
with large deviation
Fault occurs when the
dome device is in tilt
movement. It may be
caused by obstacle of
camera of other object,
which lead to early tilt
movement
Check and adjust the mechanical
installation
Wrong setting
Set the protocol, baud rate and
address of dome device
9
Self-test is normal,
but cannot control
Improper connection of
control cable
Check the circuit
Overload or too long
distance transmission
Add driver
Improper
contact
of
control cable
Check the circuit
slip ring is demage
Replace slip ring
10
Insensitive control of
dome device
RS-485
protective
discharge
arresters
broken
Change 485 protective discharge
arresters
Mostly happen in the
connection
11
Call out function fails
System failure caused by
noise interference
Restart the dome device
12
Auto action of dome
device periodically
No transmission auto “call
back” function is set to the
dome device
Called this setting
13
One dome working
well while the other
does
not
under
identical operaion
Something wrong with the
setting or wiring
check the setting and wiring
again