6.Back Light              ON/OFF          <<Back light

   

On/Off

   

Joystick left or right to select

 

7.Picture Flip              ON/OFF        <<Picture flip

   

On/Off

 

Joystick left or right to select

 

8.Picture LR Rev        ON/OFF

       

<<Picture left and right reverse

 

On/Off

   

Joystick left or right to select

 

9.Picture Stable          ON/OFF

       

<<Picture stabilized

 

On/Off 

Joystick left or right to select

 

10

Day/Night            ON/OFF      <<Black/white and color switch

 

On/Off

     

Joystick left or right to select 

11.    F-OSD                ON/OFF

     

<<Camera function display

 

On/Off   

Joystick left or right to select

 

IRIS CLOSE to Exit 

6.Function Programming

 

<<Special function programming

 

Press OPEN or Joystick left or right to enter

 

1.PTZ Tour (Pattern)    <<Pan/Tilt/Zoom tour programming

 

Press OPEN or Joystick left or right to enter

 

       

1.Number                  ( 1 ~~ 3 )                <<PTZ tour number       

Joystick left or right to select

 

        2.Name              _ _ _ _ _ _ _ _                <<Edit PTZ name 

Press OPEN or Joy stick left or right to enter

 

 

 

 

 

 

 
 

 

        3.Program a Tour                          <<Enter PTZ tour programming     

Press OPEN or Joy stick left or right to enter

 

 

 

 

       

4.Run a Tour                          <<Run Pan/Tilt/Zoom tour (pattern)   

Press OPEN or Joy stick left or right to enter

 

 

 

        5.Delete a Tour                                <<Delete PTZ tour. 

  Press OPEN or Joy stick left or right to enter

 

 

 

 

 

 

        6. Name Display              ON/OFF        <<PTZ tour name display    On/Off 

  Joy stick left or right to select

 

                      IRIS CLOSE to Exit 

_ _ _ _ _ _ _ _   

 

 

0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P 

Q R S T U V W X Y Z _ 

IRIS CLOSE When Done 

IRIS OPEN to Begin 

IRIS CLOSE to Exit 

Call out 

Are you sure to do this? 

IRIS OPEN to Confirm 

IRIS CLOSE to Cancel 

<<Joystick  left  or  right  when  programming  to  select 

preshot and press

 OPEN

 to confirm. 

Joystick left or right to select (0~~9 or A~~Z). 

Press

 OPEN

 to confirm selection.   

Press 

CLOSE

  to  exit  or  return  to  upper  stage 

menu when programming is done. 

<<Press OPEN to confirm and start programming. 

<<Press CLOSE to exit the programming and return to upper stage menu. 

<< Reminder: are you sure to do this.Press OPEN to confirm. 

Press 

CLOSE

 to exit and return to upper stage menu. 

Содержание DM597

Страница 1: ...V1 1 User Manual TeleEye DM597 DM599 High Speed Dome Before attempting to install or operate on this produce Please read this manual carefully and keep it for future use...

Страница 2: ...ID 11 Chapter Three Fast Operation Guide of Dome Device I Wiring 12 II Setting protocol and baud rate 12 III Setting dome device address 13 IV Install camera 13 V Connect the power of dome device 13 V...

Страница 3: ...t the view angle can be 90 or 92 degree 5 Pan manual operation speed can be 0 1 to 280 degree per second 6 Tilt manual operation speed can be 0 1 to 120 degree per second 7 128 pershot positions A fix...

Страница 4: ...gentina CAMERIO is a trademark of Signal Communications Limited and is registered in Australia Japan Korea New Zealand Taiwan and Argentina All other trademarks are the property of their respective ow...

Страница 5: ...oof and other protecting measures should be carried out 6 Please avoid exposing the Dome video camera to rain or the humidity etc Please do not use the product in humid place If the video camera is in...

Страница 6: ...crew holes Fig III 1 Fig III 2 Step one Aim the open end of shield dome at the lens of camera Aim the 4 holes on the shield to the 4 M3 screw holes on the dome device as indicated in figure III 2 Step...

Страница 7: ...ded to wear cotton gloves when operate 2 As shown in the figure below first take the flexible flat cable through connector above the base plate and buckle it on the connector Then buckle the cable on...

Страница 8: ...V1 1 7 V Install Bend Tube Style Bracket Fig V 1 Connecting the dome to the wall mount with the bracket Fig V 2 Wall mount bracket installation...

Страница 9: ...ce is power on 2 Multi dome device connection When connecting many dome devices together the user can embed multi device system with auxiliaries such as arrester device video matrix DVR and alarm box...

Страница 10: ...e On Off status Protocol type 1st digit 2nd digit 3rd digit 4th digit 5th digit 6th digit PELCO D ON ON OFF OFF PELCO P OFF OFF ON OFF TeleEye DM2 ON ON ON OFF Dome device controller Image displayer P...

Страница 11: ...0 OFF OFF 4800 OFF ON 9600 ON OFF 19200 ON ON This figure shows protocol of PELCO D Baud rate of 2400 Setting address for dome device this figure shows the address of dome device No 1 On Off switch Se...

Страница 12: ...V1 1 11...

Страница 13: ...s Protocol PELCO D Baud rate 2400 bps Please refer to detailed parameter in next chapter This dip switch located on PCB in the dome device Protocol setting Baud rate setting Image displayer Cables RS...

Страница 14: ...ing of protocol of dome device is auto detection the protocol of keyboard controller can be set arbitrarily But its baud rate should be set identical with that of the dome device VII Start testing Whe...

Страница 15: ...reshot setup options 1 Numder 1 Preshot number selection Press OPEN or Joy stick left or right to enter The default number after entering is 001 hundred bit ten bit single bit Joy stick left or right...

Страница 16: ...CLOSE When Done _ _ _ _ _ _ _ _ 0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z _ IRIS CLOSE When Done IRIS CLOSE When Done IRIS CLOSE When Done Press OPEN or joystick left or...

Страница 17: ...ft or right to enter 1 Default Function P V T Select default function Preshot Tour PTZ Press OPEN or Joy stick left or right to enter 2 Number 1 Function number selection Press OPEN or Joy stick left...

Страница 18: ...estore default setting Press OPEN or Joy stick left or right to enter 3 Color system PAL NTSC PAL NTSC switch Joy stick left or right to select 4 Scan Camera Reset Null Restart dome camera Press OPEN...

Страница 19: ...2 Change Name Loc Change display location of name Press OPEN or Joystick left or right to enter 3 Name Display ON OFF Name display On Off Joystick left or right to select IRIS CLOSE to Exit 4 Mask Se...

Страница 20: ...to enter 3 Program a Tour Enter PTZ tour programming Press OPEN or Joy stick left or right to enter 4 Run a Tour Run Pan Tilt Zoom tour pattern Press OPEN or Joy stick left or right to enter 5 Delete...

Страница 21: ..._ _ 16 IRIS CLOSE When Done Joystick arbitrarily to move the cursor and stop the cursor at place of programming Press OPEN to enter the selection Press OPEN continuously to select P Preshot T self stu...

Страница 22: ...alarms Press OPEN or Joystick left or right to enter This function is not available at the moment Name Num E N 1 _ _ _ 2 _ _ _ 3 _ _ _ 4 _ _ _ IRIS CLOSE to Exit P V T 1 128 0 0 1 2 3 4 5 6 7 8 9 IRIS...

Страница 23: ...on and focus 3 Input the preset number 4 Press ENTER 5 Repeat step 2 to step 4 if you want to set more preset point 6 Press set key to exit Call Preset N PRESET 1 Input the preset number 2 Press ENTER...

Страница 24: ...ate is slow If S is within 81 160 the scan rate is medium If S is within 161 250 the scan rate is high Focus Control Generally the camera will automatically adjust the focus to get clearer image based...

Страница 25: ...ronic signal noise or the camera is directed to the monitor screen Grounding the dome device or shut off the surrounding big electronic devices electric HF signal generating equipment or rotate the ca...

Страница 26: ...ce transmission Add driver Improper contact of control cable Check the circuit slip ring is demage Replace slip ring 10 Insensitive control of dome device RS 485 protective discharge arresters broken...