PROTÉGÉ ZM
PORTABLE, ZERO-MAINTENANCE, SINGLE-GAS MONITOR
OPERATION
087-0047, Rev. G/December 2019
3-1
3. OPERATION
3.1. Operating the Monitor
In the absence of gas, the LCD displays life remaining. If gas is present, the display automatically
shows the gas concentration and a battery icon.
To activate the monitor, press and hold the front button for about five (5) seconds. On activation,
the monitor vibrates, flashes and sounds an audible alarm. A successful activation will display 24
months of life remaining.
3.1.1. MONITOR LCD DISPLAY
Figure 3-1: Monitor LCD Indicators
Figure 3-1: Monitor LCD Indicators
WARNING: IF THE MONITOR FAILS TO RESPOND PROPERLY UPON START UP, OR
IF CALIBRATION IS OUT OF DATE, DO NOT USE THE DEVICE UNTIL IT
HAS BEEN PROPERLY CALIBRATED. FAILURE TO DO SO COULD
RESULT IN DEATH OR INJURY.
NOTE: You can change the monitor’s default display using the IR Connect Software.
WARNING: YOU MUST FAMILIARIZE YOURSELF WITH THE ICONS IN BOTH THE
NON-ALARM AND ALARM STATES.
WARNING: DO NOT USE IF THE DISPLAY IS MISSING ICONS OR CANNOT BE
CLEARLY READ.
Alarm Condition
Self Test Check
Test Reminder
Gas Type
Alarm Conditions
Life Remaining
Infra Red Data Transfer
Gas Reading Units
Time Since Last Maximum Exposure / Life Remainnng
Life Remaining or Gas Reading
Battery Indicator
Gas Reading Units
Reading Displayed is
Last Maximum Exposure