Page 25 of 42
10.7.
SETTING RATIO CONTROL PARAMETERS
Enabling Ratio Control
Ratio control is achieved through the
SETUP/CAL
menu. Ratio Control is activated by selecting channel
number one (1) and enabling it as master. After enabling channel one, the operator may assign the
channels that will follow its signal by some factor.
Press the
MODE
key and then
3 + ENTER
. Select channel one by pressing
1 + ENTER
. Choose
RATIO
by pressing the
6
key
+ ENTER
. Channel one (1) is enabled as the master when you press
2 +
ENTER
.
After enabling
RATIO
control, a series of menus labeled
SLAVE A
,
SLAVE B
and
SLAVE C
will be
displayed. These menus correspond to channels 2, 3 and 4 respectively. Each of the channels, 2 through
4, can be enabled or disabled individually. For example, pressing the
1
key
+ ENTER
while
SLAVE A
is
being displayed will eliminate channel two (2) from ratio control and allow channel two to work normally
as an independent channel. Pressing the number
2
key
+ ENTER
will make channel 2 the first
SLAVE
and an
S
will appear in the first column of line two on the display. Note that, if
EXIT
is selected at any
time, the previous settings remain unchanged and the display is returned to its previously programmed
configuration.