3 – Operating software
3-22
© Teledyne Limited
DPN 402197 Issue 7.1
3.3.3.3 External data logging
DeepView allows you to record the survey data acquired by the 350 system. Note that external data
logging is defaulted to on.
Figure 3-13: External Output Configuration and Serial Port menu
3.3.3.4 Load factory defaults
Selecting this option will present a dialog box. Acceptance of this dialog will result in the SEP settings
being returned to their factory defaults. Certain parameters within DeepView will also be returned to
their default states (see
Table 3-5: External Output Configuration
External Output Configuration
Note that external logging is defaulted to on
.
Output type:
In 350 mode, the system always outputs a sentence which combines the signal and coordinate
information. See
for a description of these data formats.
Output Rate:
The SDC can transmit data to the data logger at either four records or one record per second.
The default setting is four records per second.
You should consider the available storage space and the desired linear track resolution for the
survey before you decide between these alternatives.
External Out-
put Enabled
This box must be checked to enable the external output. If it is enabled, then a tick will appear
against the “external output” item in the “configuration” menu.
Configure
External Serial
Port
Options to configure, COM Port, Baud Rate, Data Bits, Parity and Stop Bits.
Table 3-6: Factory System Defaults
Parameter
Default Value
Tone Frequency Reminder Inter-
val
30 mins
Video Overlay Parameters
COM5, 9600, 8, n, 1