2105 Interface Module
Section 2 Installation and Operation
2-24
To record sample events and bottle numbers, select Set Up Data
Storage... on the Sampler tab. In the Data Storage Setup window
(Figure 2-25), select the check box next to Enable Logging.
Figure 2-25 Data Storage Setup window
2.12 Sampler “Pass Thru”
Mode
The 2105 module offers a “Pass Thru” mode which, when acti-
vated, allows you to remotely access a 6712 or Avalanche
sampler’s configuration settings.
The “Pass Thru” feature allows full remote control of a 6712’s (or
Avalanche’s) keypad functions. With this access, you can view or
modify all program and configuration settings, and also view
stored reports, current status, and data values. You can start a
program, modify the current program, or stop an active program.
This feature is helpful for applications such as storm monitoring
where the need to adjust program operation due to pending
events is often necessary.
Note
If you use this feature, it is important that you follow the steps
in Table 2-2. Make sure you close all active menus and close
the terminal emulation connection to the sampler, or the 2105
will remain in Pass Thru mode. While in Pass Thru mode, the
2105 will be unable to push data, send alarms, or accept
incoming communications.
If you are using CSD service and need to terminate the Pass
Thru mode, log back into the terminal emulation program and
follow steps 10-14 in Table 2-2.
If you are using SOIP service and you lose communications
with the module while in Pass Thru mode, you will need to visit
the site and cycle the power to restore wireless communica-
tions.
Содержание 2105
Страница 2: ......
Страница 4: ......
Страница 10: ...2105 Interface Module Table of Contents viii ...
Страница 29: ...2105 Interface Module Section 2 Installation and Operation 2 11 Figure 2 12 Site Information screen ...
Страница 36: ...2105 Interface Module Section 2 Installation and Operation 2 18 Figure 2 18 Wireless power control window ...
Страница 58: ...2105 Interface Module Section 2 Installation and Operation 2 40 ...
Страница 70: ...2105 Interface Module Section 3 Modbus Protocol and 2100 Output 3 12 ...
Страница 74: ...2105 Interface Module Section 4 Maintenance 4 4 ...
Страница 76: ...2105 Interface Module Appendix A Replacement Parts List A 2 A 1 1 2105 Interface Module Drawing 602002586 ...
Страница 77: ...2105 Interface Module Appendix A Replacement Parts List A 3 Drawing 602002586 ...
Страница 78: ...2105 Interface Module Appendix A Replacement Parts List A 4 Drawing 602002586 ...
Страница 79: ...2105 Interface Module Appendix A Replacement Parts List A 5 ...
Страница 80: ...2105 Interface Module Appendix A Replacement Parts List A 6 ...
Страница 81: ...2105 Interface Module Appendix A Replacement Parts List A 7 A 1 2 2191 Battery Module Drawing 602003113 ...
Страница 82: ...2105 Interface Module Appendix A Replacement Parts List A 8 ...
Страница 83: ...2105 Interface Module Appendix A Replacement Parts List A 9 A 1 3 2105Ci Antenna Drawing 602002583 ...
Страница 84: ...2105 Interface Module Appendix A Replacement Parts List A 10 ...
Страница 94: ...2105 Interface Module Appendix C Material Safety Data Sheets C 8 ...
Страница 98: ......