      Clock Configuration and Other Switch Settings

The source for the reference clock used by the analyzer to record PCI Express traffic is configurable according to below 
table for SW2. Make sure clock source in Recording Options in the PCIe Protocol Analysis application is set to External.  
Pushbutton SW3 allows the user to change the link width enabled on the interposer by pressing SW3 multiple times.

SW1: DUT Power LED Status

This switch connects the DUT power indication LEDs to the bus power. SW1 is located on the front of the interposer near SW2 and is 
configurable according to table below:

SW2: CONFIG-ANALYZER REFCLK SELECT

     

Note: 

Factory settings for all switches are ON.

SW3: Active Width Control Pushbutton

SW1: DUT Power LED Status on Interposer

SW1 Selection 

DUT PWR LED

ON 

ON: LED Connected (Default)

OFF 

OFF: LED Disconnected

SW2: REFCLK SELECT

Port B

1

2

Port A

3

4

REFCLK

ON

ON

REFCLK

ON

ON

US_CLK_IN

OFF

ON

US_CLK_IN

OFF

ON

DS_CLK_IN

ON

OFF

DS_CLK_IN

ON

OFF

N/A

OFF

OFF

N/A

OFF

OFF

Pushbutton SW3 is used to turn off the terminations and remove all loads on the unused interposer 
receivers depending on the maximum number of lanes to be analyzed. Press the pushbutton switch 
(SW3) to move to the next active width as indicated by the LEDs (next to the switch) on the interposer. 
This is useful for devices that require terminations not to be present in order to train to a lower link width.
The Active Width can be also controlled from the PCIe Protocol Analysis.

Note: 

Even though the Active Width may be lower than x16, it may be possible that the Signal Detect 

LEDs for higher lanes are ON if those lanes are transmitting signal.

5

Note: 

This switch connects the DUT power indication LEDs to the bus power. 

Содержание Everywhereyoulook PCI Express 5.0 Slot Interposer

Страница 1: ...data traffic flowing through the PCIe slot interface Connecting the interposer to a Teledyne LeCroy analyzer allows decoding and display of data flowing in both directions and across all lanes and wil...

Страница 2: ...the Interposer into the host system under test PCIe CEM slot connector 2 Install the PCIe expansion card under test DUT into the top connector on the interposer When plugging in a device with any supp...

Страница 3: ...the edge connector can be x16 x8 x4 or x1 DUT Power LED Status Switch SW1 Active Width Control Pushbutton SW3 Signal Detect LEDs A C B D Gen5 Straight Cable x4 PE027UCA X Link Width Status LEDs Upstre...

Страница 4: ...Summit T54 Analyzer with Gen5 PHY PCI Express 5 0 x8 Slot Interposer Upstream 7 0 Downstream 7 0 Gen5 Y Cable x8 PE028UCA X Connection diagram for single port up to x8 using a Gen5 x8 Interposer and...

Страница 5: ...1 Selection DUT PWR LED ON ON LED Connected Default OFF OFF LED Disconnected SW2 REFCLK SELECT Port B 1 2 Port A 3 4 REFCLK ON ON REFCLK ON ON US_CLK_IN OFF ON US_CLK_IN OFF ON DS_CLK_IN ON OFF DS_CLK...

Страница 6: ...of the DUT s metal flange Fully insert the DUT in the top connector of the interposer Then use the thumbscrew in the DUT retention clamp to secure the DUT See the drawings below DUT Retention Clamp F...

Страница 7: ...nstallation of the half height bracket The diagrams below show a x8 Interposer but the same procedure can be used for any link width Gen5 Interposer x1 x4 or x16 Gen5 x8 Interposer with Full Height Br...

Страница 8: ...or penalty Teledyne LeCroy Customer Support Online Download Periodically check the Teledyne LeCroy Protocol Solutions Group web site for software updates and other support related to this product Soft...

Отзывы: