background image

  

 

 Interconnection Overview with Summit T54 Analyzer

PCIe Card Under Test

12V DC

from 

adapter 

supplied

Summit T54 Analyzer

(with Gen5 PHY)

Configuration 

switches and clock 

inputs 

(see table below): 

SW2

PCIe Slot from Host System Under Test

Depending on the 

Interposer, the edge 
connector can be 

x16, x8, x4 or x1

DUT Power LED 
Status Switch: SW1

Active Width Control 
Pushbutton: SW3

Signal

Detect

LEDs

A

C

B

D

Gen5 Straight Cable x4

(PE027UCA-X)

Link Width
Status LEDs

Upstream Clock In

Downstream Clock In

Connection to 

Retimer Board*

Connection from

Retimer Board*

* For information about use of Retimer 
Board see 

Gen5 Slot Retimer 

User Manual and Quick Start Guide

Connection diagram for single port up to x4 using a Gen5 x8 Interposer 

Содержание Everywhereyoulook PCI Express 5.0 Slot Interposer

Страница 1: ...data traffic flowing through the PCIe slot interface Connecting the interposer to a Teledyne LeCroy analyzer allows decoding and display of data flowing in both directions and across all lanes and wil...

Страница 2: ...the Interposer into the host system under test PCIe CEM slot connector 2 Install the PCIe expansion card under test DUT into the top connector on the interposer When plugging in a device with any supp...

Страница 3: ...the edge connector can be x16 x8 x4 or x1 DUT Power LED Status Switch SW1 Active Width Control Pushbutton SW3 Signal Detect LEDs A C B D Gen5 Straight Cable x4 PE027UCA X Link Width Status LEDs Upstre...

Страница 4: ...Summit T54 Analyzer with Gen5 PHY PCI Express 5 0 x8 Slot Interposer Upstream 7 0 Downstream 7 0 Gen5 Y Cable x8 PE028UCA X Connection diagram for single port up to x8 using a Gen5 x8 Interposer and...

Страница 5: ...1 Selection DUT PWR LED ON ON LED Connected Default OFF OFF LED Disconnected SW2 REFCLK SELECT Port B 1 2 Port A 3 4 REFCLK ON ON REFCLK ON ON US_CLK_IN OFF ON US_CLK_IN OFF ON DS_CLK_IN ON OFF DS_CLK...

Страница 6: ...of the DUT s metal flange Fully insert the DUT in the top connector of the interposer Then use the thumbscrew in the DUT retention clamp to secure the DUT See the drawings below DUT Retention Clamp F...

Страница 7: ...nstallation of the half height bracket The diagrams below show a x8 Interposer but the same procedure can be used for any link width Gen5 Interposer x1 x4 or x16 Gen5 x8 Interposer with Full Height Br...

Страница 8: ...or penalty Teledyne LeCroy Customer Support Online Download Periodically check the Teledyne LeCroy Protocol Solutions Group web site for software updates and other support related to this product Soft...

Отзывы: